SPECIAL FUNCTIONS

Counter modes overview (optional function of DI0 to DI3 inputs

Counter mode 

Counter 1 object

Counter 2 object

One one-way counter

DI0 - UP

DI2 - UP

Two one-way counters

DI0 - UP
DI1 - UPB

DI2 - UP
DI3 - UPB

Two-way counter

DI0 - UP
DI1 - DOWN

DI2 - UP
DI3 - DOWN

Counter with controlled direction

DI0 - CLK
DI1 - DIR

DI2 - CLK
DI3 - DIR

Basic incremental encoder

DI0 - V
DI1 - G

DI2 - V
DI3 - G

Two-way counter with reset and cap-
turing

DI0 - UP
DI1 - DOWN
DI2 - CLR
DI3 - CAP

-

Counter with controlled direction and
with reset and capturing

DI0 - CLK
DI1 - DIR
DI2 - CLR
DI3 - CAP

-

Incremental encoder with reset and
capturing

DI0 - V
DI1 - G
DI2 - NI
DI3 - MD

-

Measuring pulse length

input DI0 - DI3 selectable 
during operation

-

Measuring period and shift phase
(both functions switched during opera-
tion)

period: input DI0 - DI3 
selectable during operation
phase shift:
between DI0 and DI1

-

Overview of abbreviations of various signals:
UP - pulse input for counter incrementation
UPB- pulse input for B counter incrementation
DOWN - pulse input for counter decrementation 
CLK - pulse input for counter
DIR - counter direction
CLR - counter reset
CAP- capturing counter value
V

- incremental encoder first track

G

- incremental encoder second track

NI

- incremental encoder clearing pulse

MD - measuring contact

11

TXV 113 01

Summary of Contents for TECOMAT FOXTROT IB-1301

Page 1: ...2011 3rd edition March 2011 Podrobn u ivatelsk dokumentace je k dispozici na firemn m CD INFO a na www tecomat cz pod n zvem Programovateln automaty TECOMAT FOXTROT obj slo TXV 004 10 Detailed user d...

Page 2: ......

Page 3: ...n Nap jec nap t typ 24 V DC Intern ji t n Ne Typick p kon 1 W Maxim ln p kon 2 W Galvanick odd len nap jen od vnit n ch obvod Ne Kryt SN EN 60529 1993 idt IEC 529 1989 IP10B Hmotnost 105 g Rozm ry 90...

Page 4: ...ick odd len od vnit n ch obvod Ano Diagnostika signalizace vybuzen ho vstupu LED na panelu modulu Spole n vodi minus plus Vstupn nap t pro log 0 UL max 5 V DC min 5 V DC pro log 1 UH min 15 V DC typ 2...

Page 5: ...CLR DI3 CAP ta s zen m sm ru s nulov n m a zachycen m DI0 CLK DI1 DIR DI2 CLR DI3 CAP IRC s nulov n m a zachycen m DI0 V DI1 G DI2 NI DI3 MD M en d lky pulzu za chodu voliteln vstup DI0 DI3 M en perio...

Page 6: ...zsahu zak zky a zp sobu p epravy do p epravn ho obalu opat en ho p epravn mi etiketami a ostatn mi daji nutn mi pro p epravu P eprava od v robce se prov d zp sobem dohodnut m p i objedn v n P eprava v...

Page 7: ...en modulu IB 1301 7 TXV 113 01 COM2 DI4 DI5 DI6 DI7 DI8 DI9 DI10 DI11 TCL2 TCL2 GND 24V COM1 DI0 DI1 DI2 DI3 TC LINE 24 V DC DIGITAL INPUTS DIGITAL INPUTS IB 1301 ADR 0 1 2 3 4 5 6 7 8 9 RUN BLK 24 V...

Page 8: ...V 004 10 8 DR BA P i dodr en v eobecn ch podm nek pro instalaci nevy aduje modul dnou dr bu kony p i kter ch je t eba prov st demont n kter sti modulu se prov d j v dy p i odpojen m nap jec m nap t Pr...

Page 9: ...solation from internal circuits No Coverage SN EN 60529 1993 idt IEC 529 1989 IP10B Height 105 g Dimensions 90 53 65 mm 1 2 OPERATIONAL CONDITIONS Class of ambient influence SN 33 2000 3 1995 mod IEC...

Page 10: ...s Diagnostics indication of energized input by LED on module panel Common pole for the group minus plus Input voltage for log 0 UL max 5 V DC min 5 V DC for log 1 UH min 15 V DC typ 24 V DC max 30 V D...

Page 11: ...pturing DI0 CLK DI1 DIR DI2 CLR DI3 CAP Incremental encoder with reset and capturing DI0 V DI1 G DI2 NI DI3 MD Measuring pulse length input DI0 DI3 selectable during operation Measuring period and shi...

Page 12: ...containing all the necessary data for transportation The goods is transported from the manufacture s facilities as agreed when placing an order Transportation of the goods by the customer must be purs...

Page 13: ...ection of IB 1301 module 13 TXV 113 01 COM2 DI4 DI5 DI6 DI7 DI8 DI9 DI10 DI11 TCL2 TCL2 GND 24V COM1 DI0 DI1 DI2 DI3 TC LINE 24 V DC DIGITAL INPUTS DIGITAL INPUTS IB 1301 ADR 0 1 2 3 4 5 6 7 8 9 RUN B...

Page 14: ...hen following general installation instructions are kept the module does not require any other maintenance Should dismantling of some part of the module be necessary supply voltage must always be OFF...

Page 15: ...Notes...

Page 16: ...Teco a s Havl kova 260 280 58 Kol n IV Czech Republic URL www tecomat cz e mail teco tecomat cz...

Reviews: