13
Group 00- The basic parameters group
No. Description
Range
Factory
Setting
Note
00-00
control
mode
0: V/F mode
0
1: SLV mode
00-01
Motor
rotation
0: Forward
1: Reverse
0 *1
00-02
Main Run
Source
Selection
0: Keypad
1
1: External
Run/Stop Control
2: Communication
00-03
Alternative
Run
Source
Selection
0: Keypad
0
1: External Run/Stop
Control
2: Communication
00-04
Operation
modes for
external
terminals
0: Forward/
Stop-Reverse/Stop
0
◇
1: Run/
Stop-Reverse/Forward
2: 3-Wire Control
Mode-Run/Stop
3: 2-Wire
self-holding
Run/Stop
00-05
Main
Frequency
Source
Selection
0: Keypad
2
1: Potentiometer
on Keypad
2: External AVI
Analog Signal
Input
3: External ACI
Analog Signal
Input
4: External
Up/Down
Frequency Control
5: Communication
setting Frequency
6: PID output
frequency
00-06
Alternative
Frequency
Source
Selection
0: Keypad
0
1: Potentiometer
on Keypad
2: External AVI
Analog Signal
Input
3: External ACI
Analog Signal
Input
4: External
Up/Down
Frequency Control
5: Communication
setting Frequency
6: PID output
frequency.
00-07
Main and
Alternative
Frequency
Command
modes
0: Main Or
Alternative
Frequency
1: Main frequency
+ Alternative
Frequency
0
Group 00- The basic parameters group
No. Description
Range
Factory
Setting
Note
00-08
Communicat
ion
Frequency
Command
0.00~599.00
*4
00-09
Frequency
command
Save mode
(Communica
tion mode)
0: Save the
frequency before
power down
1: Save the
communication
frequency
0
00-10
Initial
Frequency
Selection
( keypad
mode)
0: by Current
Frequency
Command
0
1: by 0 Frequency
Command
2: by 00-11
00-11
Initial
Frequency
Keypad
mode
0.00~599.00
50.00/
60.00
00-12
Frequency
Upper Limit
0.01~599.00
50.00/
60.00
00-13
Frequency
Lower Limit
0.00~598.99 0.00
00-14
Acceleration
Time 1
0.1~3600.0 10.0
*1
00-15
Deceleration
Time 1
0.1~3600.0 10.0
*1
00-16
Acceleration
Time 2
0.1~3600.0 10.0
*1
00-17
Deceleration
Time 2
0.1~3600.0 10.0
*1
00-18
Jog
Frequency
1.00~25.00 2.00
*1
00-19
Jog
Acceleration
Time
0.1~25.5 0.5
*1
00-20
Jog
Deceleration
Time
0.1~25.5 0.5
*1
00-21
Application
Field
Selection
0: Disable
3
: Constant
Pressure
Application
0
◇
Group 01- V/F Pattern selection &
Setup
No. Description
Range
Factory
Setting
Note
01-00
Volts/Hz
Patterns
1~7 1/4
01-01
V/F Max
voltage
200V:170.0
~
264.0
400V:323.0
~
528.0
Based on
13-08
01-02
Max
Frequency
0.2 ~ 599.00
50.00/
60.00
Summary of Contents for L510-101-SH1-N
Page 1: ......
Page 30: ...2 1 4 5 5 1 5 10 50 1 95 RH 1 10 50 10 40 1 6...
Page 31: ...3 2 2 1 NFB AC NFB NFB NFB 200mA 0 1 V TYPE AC AC EMC R S T E...
Page 35: ...7 2 2 4 PNP 400V L510 401 SH3 F P L510 402 SH3 F P L510 403 SH3 F P...
Page 39: ...11 3 3 1 00 01 V F 02 03 04 05 06 07 08 09 10 PID 11 12 13 14 PUMP 1 v07 2 3 4...
Page 63: ...L510s EMC EMC EMC 2P2 2P5 201 202 203...
Page 64: ......