18 

Group 06- Auto Run(Auto Sequencer) 

function 

No.  Description 

Range 

Factory

Setting

Note

06-04 

Auto _ Run 
Mode 
frequency 
command 4 

0.00 *1 

06-05 

Auto _ Run 
Mode 
frequency 
command 5 

0.00 *1 

06-06 

Auto _ Run 
Mode 
frequency 
command 6 

0.00 *1 

06-07 

Auto _ Run 
Mode 
frequency 
command 7 

0.00 *1 

06-08 

~   

06-15 

Reserved 

06-16 

Auto_ Run 
Mode 
running time 
setting 0 

0.0 ~ 3600.0 

0.0 *1 

06-17 

Auto_ Run 
Mode 
running time 
setting 1 

0.0 *1 

06-18 

Auto_ Run 
Mode 
running time 
setting 2 

0.0 *1 

06-19 

Auto_ Run 
Mode 
running time 
setting 3 

0.0 *1 

06-20 

Auto_ Run 
Mode 
running time 
setting 4 

0.0 *1 

06-21 

Auto_ Run 
Mode 
running time 
setting 5 

0.0 *1 

06-22 

Auto_ Run 
Mode 
running time 
setting 6 

0.0 *1 

06-23 

Auto_ Run 
Mode 
running time 
setting 7 

0.0 *1 

06-24 

~   

06-31 

Reserved 

06-32 

Auto_ Run 
Mode 
running 
direction 0 

0: Stop 
1: Forward 
2: Reverse 

0  

Group 06- Auto Run(Auto Sequencer) 

function 

No. Description

Range 

Factory

Setting

Note

06-33

Auto_ Run 
Mode 
running 
direction 1 

0  

06-34

Auto_ Run 
Mode 
running 
direction 2 

0  

06-35

Auto_ Run 
Mode 
running 
direction 3 

0  

06-36

Auto_ Run 
Mode 
running 
direction 4 

0  

06-37

Auto_ Run 
Mode 
running 
direction 5 

0  

06-38

Auto_ Run 
Mode 
running 
direction 6 

0  

06-39

Auto_ Run 
Mode 
running 
direction 7 

0  

 

 

Group 07- Start/Stop command setup 

No. Description

Range 

Factory

Setting

Note

07-00

Momentary 
Power Loss 
and Restart

0: Momentary 
Power Loss and 
Restart disable 
1: Momentary 
power loss and 
restart enable 

0  

07-01

Auto Restart 
Delay Time

0.0~6000.0 0.0 

 

07-02

Number of 
Auto Restart 
Attempts 

0~10 0 

 

07-03

Reset Mode 
Setting 

0: Enable Reset 
Only when Run 
Command is Off 
1: Enable Reset 
when Run 
Command is On or 
Off 

0  

07-04

Direct 
Running 
After Power 
Up 

0: Enable Direct 
run on power up 
1: Disable Direct 
run on power up 

1  

07-05

Delay-ON 
Timer 

1.0~300.0 1.0 

 

07-06

DC Injection 0.10 ~ 10.00 

1.5 

 

Summary of Contents for L510-101-SH1-N

Page 1: ......

Page 2: ...se the user may be required to apply corrective measures Caution Work on the device system by unqualified personnel or failure to comply with warnings can result in severe personal injury or serious d...

Page 3: ...ink capacitors remain charged for five minutes after power has been removed It is not permissible to open the equipment until 5 minutes after the power has been removed Caution The Inverter should be...

Page 4: ...install a magnetic contactor Do not use the magnetic contactor as the run stop switch for the inverter AC line reactor for power quality When inverters are supplied by a high capacity power source 60...

Page 5: ...ingle phase NPN input Model 100V L510 1P2 SH1 N L510 1P5 SH1 N L510 101 SH1 N 200V L510 2P2 SH1 F N L510 2P5 SH1 F N L510 201 SH1 F N L510 202 SH1 F N L510 203 SH1 F N 1 Data 2 Data 3 Data 4 Reserved...

Page 6: ...5 2 2 2 Single phase PNP input Model 200V L510 2P2 SH1 F P L510 2P5 SH1 F P L510 201 SH1 F P L510 202 SH1 F P L510 203 SH1 F P 1 Data 2 Data 3 Data 4 Reserved 5 Reserved 6 Data 7 5V 8 GND...

Page 7: ...phase NPN input Model 200V L510 2P2 SH3 N L510 2P5 SH3 N L510 201 SH3 N L510 202 SH3 N L510 203 SH3 N 400V L510 401 SH3 N L510 402 SH3 N L510 403 SH3 N 1 Data 2 Data 3 Data 4 Reserved 5 Reserved 6 Da...

Page 8: ...7 2 2 4 Three phase PNP input Model 400V L510 401 SH3 F P L510 402 SH3 F P L510 403 SH3 F P 1 Data 2 Data 3 Data 4 Reserved 5 Reserved 6 Data 7 5V 8 GND...

Page 9: ...3 F NPN PNP input is selected by SC terminal If you need to use NPN input please you shorted 24V and SC terminal If you need to use PNP input please you shorted COM and SC terminal Notes If the SC ter...

Page 10: ...L3 L2 L3 N P externally connected braking resistor BR T1 Inverter output connect to U V W terminals of motor T2 T3 Ground terminal P BR for 205 208 210 401 402 403 405 408 410 415 series Single phase...

Page 11: ...er to group3 24 VDC 4 5 mA Optical coupling isolation Max voltage30 Vdc Input impedance 6k S2 S3 S4 S5 10V Built in Power for an external speed potentiometer 10V Max current 20mA AVI Analog voltage in...

Page 12: ...eference point for S1 S5 S1 S5 Multi function input terminals refer to group3 24 VDC 4 5 mA Optical coupling isolation Max voltage30 Vdc Input impedance 6k 10V Built in Power for an external speed pot...

Page 13: ...o Run Auto Sequencer function Group 07 Start Stop command setup Group 08 Drive and motor Protection Group 09 Communication function setup Group 10 PID function setup Group 11 Performance control funct...

Page 14: ...quency Command modes 0 Main Or Alternative Frequency 1 Main frequency Alternative Frequency 0 Group 00 The basic parameters group No Description Range Factory Setting Note 00 08 Communicat ion Frequen...

Page 15: ...Gain 0 100 0 01 18 Auto torque Compensatio n Frequency 1 30 5 00 2 Group 02 Motor parameters No Description Range Factory Setting Note 02 00 Motor No Load Current by motor nameplate 02 01 Motor Rated...

Page 16: ...wn Frequency modes 0 Preset frequency is held as the inverter stops and the UP Down function is disabled 0 1 Preset frequency is reset to 0 Hz as the inverter stops Group 03 Multi function Digital Inp...

Page 17: ...Selection 0 Positive 1 Negative 0 1 04 05 AVI Slope 0 Positive 1 Negative 0 1 04 06 ACI Signal Verification Scan rate 1 200 50 04 07ACI Gain 0 1000 100 1 Group 04 Analog signal inputs Analogue output...

Page 18: ...equency Selections No Description Range Factory Setting Note 05 30 Preset Speed6 Dec time 10 0 1 05 31 Preset Speed7 Acc time 10 0 1 05 32 Preset Speed7 Dec time 10 0 1 Group 06 Auto Run Auto Sequence...

Page 19: ...Forward 2 Reverse 0 Group 06 Auto Run Auto Sequencer function No Description Range Factory Setting Note 06 33 Auto_ Run Mode running direction 1 0 06 34 Auto_ Run Mode running direction 2 0 06 35 Aut...

Page 20: ...Disable Trip Prevention During Acceleration xxx0x Enable Trip Prevention During Deceleration xxx1x Disable Trip Prevention During Deceleration xx0xx Enable Trip Prevention in Run Mode xx1xx Disable Tr...

Page 21: ...rrent protection level 0 0 60 0 0 0 Group 08 Drive Motor Protection functions No Description Range Factory Setting Note 08 18 Over current protection time 0 0 1500 0 1 0 08 19 Motor Overload Protectio...

Page 22: ...Feedback D Control Reverse Characteristic 0 10 04 Feedback Gain Coefficient 0 00 10 00 1 00 1 Group10 PID function Setup No Description Range Factory Setting Note 10 05 Proportional Gain 0 0 10 0 3 0...

Page 23: ...eed only 0 11 14 Regeneration Prevention Voltage Level 200v 300 0 400 0 400v 600 0 800 0 380 760 Group11 Performance Control functions No Description Range Factory Setting Note 11 15 Regeneration Prev...

Page 24: ...3 06 Parameter Lock 0 Enable all Functions 1 Preset speeds 05 01 05 08 cannot be changed 2 All Functions cannot be changed Except for Preset speeds 05 01 05 08 3 Disable All Function 4 Parameters 00 0...

Page 25: ...0 0 600 0 0 0 14 18 Time of Loss Pressure Detection 0 0 600 0 0 0 14 19Proportion 0 100 0 Group 14 PUMP Application Function No Description Range Factory Setting Note of Loss Pressure Detection 14 20...

Page 26: ...Limit 0 1 6553 5 6 1 14 79 Minimum Current Limit 0 1 6553 5 6 1 14 80 Current limit cumulative time 0 600 0 0 Group 14 only can be used once parameter 14 00 1 Note When 14 00 set to 1 07 12 will be s...

Page 27: ...OPBFT 1 Check feedback signal is correct 2 Check if feedback value of pressure is lower than limit of maximum pressure 14 12 FBLSS 1 Check if the proportion of loss pressure 23 19 is set correctly 2 M...

Page 28: ...flash STP1 3 The run input is active at power up refer to descriptions of 07 04 Display Description StP2 1 If the Stop key is pressed while the inverter is set to external control mode 00 02 00 03 1 t...

Page 29: ...L1 L2 L3 T1 T2 T3 50 10 50 10 40 IEC EN61800 3 EN61800 5 1 1 2 00 02 00 03 07 04 07 00 00 02 00 03 07 04 FWD REV 07 00 07 01 07 02 1 00 02 00 03 0 2 00 02 00 03 1 FWD REV 3 00 02 00 03 1 07 04 0 FWD...

Page 30: ...2 1 4 5 5 1 5 10 50 1 95 RH 1 10 50 10 40 1 6...

Page 31: ...3 2 2 1 NFB AC NFB NFB NFB 200mA 0 1 V TYPE AC AC EMC R S T E...

Page 32: ...4 2 2 2 2 1 NPN 100V L510 1P2 SH1 N L510 1P5 SH1 N L510 101 SH1 N 200V L510 2P2 SH1 F N L510 2P5 SH1 F N L510 201 SH1 F N L510 202 SH1 F N L510 203 SH1 F N...

Page 33: ...5 2 2 2 PNP 200V L510 2P2 SH1 F P L510 2P5 SH1 F P L510 201 SH1 F P L510 202 SH1 F P L510 203 SH1 F P...

Page 34: ...6 2 2 3 NPN 200V L510 2P2 SH3 N L510 2P5 SH3 N L510 201 SH3 N L510 202 SH3 N L510 203 SH3 N 400V L510 401 SH3 N L510 402 SH3 N L510 403 SH3 N...

Page 35: ...7 2 2 4 PNP 400V L510 401 SH3 F P L510 402 SH3 F P L510 403 SH3 F P...

Page 36: ...8 2 2 5 NPN PNP 200V L510 205 SH3 L510 208 SH3 L510 210 SH3 400V L510 405 SH3 F L510 408 SH3 F L510 410 SH3 F L510 415 SH3 F NPN PNP PNP 1 SC COM 2 24v S1 S5 NPN 1 SC 24V 2 COM S1 S5 SC 03...

Page 37: ...L1 L L1 L L3 N 200V L1 L L2 L3 N 400V L1 L2 L3 L2 L3 N P BR T1 U V W T2 T3 P BR 205 208 210 401 402 403 405 408 410 415 200V 200V 205 208 210 400V L1 L L2 L3 N T1 T2 T3 L1 L L2 L3 N T1 T2 T3 L1 L2 L3...

Page 38: ...DC 04 00 0 10V 200K ACI 0 4 20mA 04 00 0 20mA 249 AO 10VDC 1mA 0 10V 2mA AGND NPN PNP 3 4 TM1 RA 250VAC 5A 30VDC 5A RA RB RC RB RC TM2 24V S1 S5 PNP 15 30mA SC NPN PNP NPN 24V SC PNP COM SC COM S1 S5...

Page 39: ...11 3 3 1 00 01 V F 02 03 04 05 06 07 08 09 10 PID 11 12 13 14 PUMP 1 v07 2 3 4...

Page 40: ...0 00 14 1 0 1 3600 0 10 0 1 00 15 1 0 1 3600 0 10 0 1 00 16 2 0 1 3600 0 10 0 1 00 17 2 0 1 3600 0 10 0 1 00 18 1 00 25 00 2 00 1 00 19 0 1 25 5 0 5 1 00 20 0 1 25 5 0 5 1 00 21 0 3 0 01 V F 01 00 V F...

Page 41: ...4 02 05 0 22 0 02 06 0 599 0 02 07 0 1 0 02 08 0 600 02 09 0 600 02 10 02 11 02 12 02 13 SLV 0 200 02 14 SLV 0 200 100 02 15 0 100 50 02 16 SLV 0 200 02 02 17 SLV 0 200 150 02 18 SLV 0 200 100 02 19 S...

Page 42: ...00 0 00 03 19 0 A 0 1 B 03 20 100 200V 240 0 400 0V 400V 500 0 800 0V 100 220 230 V 380 380 400V 690 415 460V 780 03 21 100 200V 240 0 400 0V 400V 500 0 800 0V 100 220 230 V 360 380 400V 650 415 460V...

Page 43: ...6 0 00 599 00 50 00 1 05 08 7 0 00 599 00 50 00 1 05 09 05 16 05 17 0 0 1 3600 0 10 0 1 05 18 0 0 1 3600 0 10 0 1 05 19 1 0 1 3600 0 10 0 1 05 20 1 0 1 3600 0 10 0 1 05 21 2 0 1 3600 0 10 0 1 05 22 2...

Page 44: ...1 06 20 4 0 0 3600 0 0 0 1 06 21 5 0 0 3600 0 0 0 1 06 22 6 0 0 3600 0 0 0 1 06 23 7 0 0 3600 0 0 0 1 06 24 06 31 06 32 0 0 1 2 0 06 33 1 0 1 2 0 06 34 2 0 1 2 0 06 35 3 0 1 2 0 06 36 4 0 1 2 0 06 37...

Page 45: ...xx1xx 08 06 OL1 0 0 1 OL1 08 07 OH 0 1 1 RUN 2 3 08 08 AVR 0 AVR 4 1 AVR 2 AVR stop 08 3 AVR 4 AVR stop 5 AVR stop VDC 360V 740V 08 09 0 0 1 08 10 PTC 0 0 1 2 3 08 11 PTC 0 01 10 00 0 2 08 12 1 300 60...

Page 46: ...00 06 6 0 Keypad 1 1 1 AVI 2 ACI 3 4 10 02 5 PID 10 01 PID 0 Keypad 2 1 1 AVI 2 ACI 10 PID 3 10 02 PID 0 0 100 0 50 0 1 10 03 PID 0 PID 1 PID D 2 PID D 3 PID D 4 PID D 5 PID D 6 PID D 7 PID D 8 PID D...

Page 47: ...2 S 0 0 4 0 0 00 11 06 3 S 0 0 4 0 0 00 11 07 4 S 0 0 4 0 0 00 11 08 1 0 00 599 00 0 00 1 11 09 2 0 00 599 00 0 00 1 11 10 3 0 00 599 00 0 00 1 11 11 0 00 30 00 0 00 1 11 12 11 13 0 0 11 1 2 11 14 200...

Page 48: ...1 0 23 3 13 04 2 0 65535 3 13 05 0 1 0 3 13 06 0 1 5 01 5 08 2 5 01 5 08 3 13 06 4 00 00 0 13 13 07 00000 65535 000 00 13 08 1150 50Hz 220V 380V 1160 60Hz 220V 380V 1250 50HZ 230V 400V 1260 60Hz 230V...

Page 49: ...1 1 14 22 0 00 599 00 45 00 14 23 0 1 1 14 24 14 20 0 0 00 65 00 14 20 1 0 10 1 14 25 0 0 200 0 30 0 14 26 0 1 3600 0 12 0 14 PUMP 14 27 0 1 3600 0 35 0 14 28 0 00 00 12 0 00 14 29 0 240 3 14 30 0 30...

Page 50: ...12 0 V1 13 4 41 4 1 1 OV LV 1 2 3 OH 1 2 OH C 1 2 CtEr HPErr 13 00 EPr EEPROM COt Err4 OC A 1 2 3 4 5 IGBT OC C 1 2 OC d OC S 1 2 3 IGBT OV C 1 2 3 PF 1 2 3 LPBFT 1 2 14 15 OPBFT 1 2 14 12 FBLSS 1 14...

Page 51: ...00 05 00 06 10 00 10 01 4 01 00 7 5 PTC AVI 6 Err5 1 2 Err6 1 2 09 00 09 05 3 CON2 GND 4 09 08 Err7 4 1 3 StP0 V F 1 3Hz 50Hz 1 5Hz 60Hz STP0 SLV 1Hz STP0 StP1 00 02 00 03 1 07 04 1 STP1 07 04 StP2 1...

Page 52: ...n adjustment and maintenance of AC drives Do not perform work on the drive while wearing loose clothing jewelry or lack of eye protection Failure to comply could result in death or serious injury Remo...

Page 53: ...andard Main Circuit Terminal Wiring UL approval requires crimp terminals when wiring the drive s main circuit terminals Use crimping tools as specified by the crimp terminal manufacturer Teco recommen...

Page 54: ...ann 10CT 690V10A 402 Bussmann 16CT 690V 16A 403 Bussmann 20CT 690V 20A 405 Bussmann 25ET 690V 25A 408 Bussmann 40FE 690V 40A 410 Bussmann 50ET 690V 50A 415 Bussmann 63ET 690V 63A Motor Over temperatur...

Page 55: ...e electronic thermal overload function is UL recognized so it does not require an external thermal overload relay for single motor operation This parameter selects the motor overload curve used accord...

Page 56: ...issement Le circuit principal doit tre correctement c bl e Pour les terminaux monophas s d approvisionnement de l utilisation des intrants R L1 T L3 et de trois bornes d entr e de l utilisation de l o...

Page 57: ...e aux bornes onduleur de sortie U T1 V T2 W T3 Ne pas brancher un contacteur ou interrupteur en s rie avec le variateur et le moteur Ne branchez pas un facteur condensateur de correction de puissance...

Page 58: ...sement la performance du moteur ou de la machine avant d utiliser grande vitesse sous peine de blessure Notez les r glages des param tres li s l unit de freinage lorsque applicable Ne pas utiliser la...

Page 59: ...BDE X O O O O O O O X O O O O O O O O O X O O O O O O O O O O O O O O O O O X O O O O O O O O O O O SJ T 11364 O GB T 26572 X GB T 26572 1000ppm RoHS 7 a 85 7 c I 100ppm RoHS 8 b 1000ppm RoHS 6 a 0 35...

Page 60: ...tabel below Motor control V f vector Nominal current Please refer to the table below Nominal apparent power Please refer to the table below Maximum operating temperature 50 for frame 2 4 40 for frame...

Page 61: ...4 0 13 9 36 83 3 42 89 2 57 92 0 37 91 1 44 94 4 59 95 8 46 96 6 64 97 4 65 97 6 3 L510 405 SH3 F 380 9 2 3 7 7 0 16 9 58 84 6 70 89 9 96 92 3 60 91 8 72 94 7 100 96 0 76 96 8 108 97 5 111 97 7 3 L51...

Page 62: ...frame 1 models Single phase 220V input Connect to L1 L L3 N Power cable should be wound three times through the ferrite cores Suitable for 202 203 frame 2 models Ground terminal Single phase 220V inpu...

Page 63: ...L510s EMC EMC EMC 2P2 2P5 201 202 203...

Page 64: ......

Reviews: