background image

 

24 MONTHS WARRANTY – valid in all UE countries  

TECNOWARE S.r.l. guarantees the product for a period of 24 months from the original date of 

purchase.  
The date of purchase is proved with the receipt of account released by the authorised reseller, 

which clearly indicates the date in which the product was sold and the product identification 

code (model and serial number). Upon request of Technical assistance, a copy of your receipt 

must be surrendered. 
This guarantee implies free reparation or free substitution of any products parts or components 

which result faulty due to defective manufacture.  In such case the transportation costs are 

covered by the guarantee service. 
In the event of irreparable fault, or should the same malfunction repeat itself, TECNOWARE 

S.r.l will provide the final decision on the product substitution. 
Any parts damaged due to the negligence or carelessness in using the product (such as failing 

to follow the correct operating instructions indicated in the user manual), violations, incorrect 

installation or maintenance operated by non authorized personnel, transportation damages, 

natural calamities, accidental causes, phenomenon not subordinated to the normal product 

functioning, non qualification of environment in which the product operates, and in any case: 

any circumstances in which one cannot date back to the  defective manufacture, will not be 

covered by the guarantee 
Compensation is excluded for: direct or in direct damages of any nature caused to people or 

objects, by the incorrect use of product; by the discontinuance of product functioning, or for 

stopping the usage due to the product servicing. 
This guarantee is valid upon the terms and conditions cited above, in all the countries belonging 

to the UE countries. 

 
 

 

CONFORMITY TO THE EUROPEAN DIRECTIVES 

 

TECNOWARE S.r.l. confirms that EVO models comply with the requirements set out in: the Low Voltage 

Directive (Safety) 73/23/EEC and following amendments, the EMC (Electro-Magnetic Compatibility) 

Directive 89/336/EEC and following amendments. 
The following standards were applied: 
Low Voltage Directive (Safety): EN62040-1-1: 2003 
EMC Directive (Electro-Magnetic Compatibility): IEC62040-2: 2001, IEC61000-3-2: 2001, IEC61000-3-3: 

2001, EN55022: 1998, IEC61000-6-4: 20011

 

 
 

PRODUCT DISPOSAL 

EVO cannot be disposed as an urban waste, but must be treated as a separate 

waste. Any violation is indictable with financial sanctions as per in force regulations.  
An incorrect waste disposal or an improper use of the same or of any parts can be 

damaging for the environment and for human health.    
A correct waste disposal of products having the dustbin symbol marked by a cross 

help to avoid negative consequences to the environment and  to human health. 

 

 

User’s manual 

21 UPS 

EVO

 

Summary of Contents for EVO 1.0

Page 1: ...EVO Uninterruptible Power Supply EVO 1 0 EVO 2 0 EVO 3 0 USER S MANUAL...

Page 2: ......

Page 3: ...CEMENT FIRST START UP 5 COMPUTER INTERFACE page 12 6 TECHNICAL CHARACTERISTICS page 13 7 SUGGESTIONS FOR A CORRECT USE page 14 MAINTENANCE BATTERY MAINTENANCE SAFETY FOR THE OPERATOR 8 ANOMALIES AND T...

Page 4: ...repair or maintenance must be performed exclusively by qualified technical personnel authorized by TECNOWARE TECNOWARE declines any responsibility if this warning is disregarded It is compulsory to g...

Page 5: ...ATIC BYPASS that directly connects the AC input line with its outlets EVO is supplied with an RS 232 communication port and USB port which can be used to signal to a generic processor or computer the...

Page 6: ...ere is an automatic SWITCHING On operation Automatic functioning test through a switch Automatic regulation to the input frequency 50 or 60 Hz Visual warnings by leds indicating operational mode and l...

Page 7: ...ed This led blue is ON when the input AC line voltage amplitude is within the specification and it indicates the UPS is working in LINE mode If LINE led flashes every second it shows that Phase line a...

Page 8: ...5 16 17 and 18 60 41 three leds are on led15 16 and 17 40 21 two leds are on led15 and led16 20 0 only one led is on led15 The LOW BAT yellow led led14 is on to warn of a LOW BATTERY condition during...

Page 9: ...the UPS from the front panel The EPO terminals are isolated and do not need an external feeding voltage REMOTE ON OFF ON 1 2 Remote Button ON OFF 3 4 Remote Button OFF The EVO models have remote ON OF...

Page 10: ...ormal closed output When UPS works normally Pin 6 and Pin 1 2 will be closed when UPS works in bypass mode Pin 6 and Pin 1 2 will be open 4 AC fail Pin 7 is the normal open output When UPS works norma...

Page 11: ...gnal showing its own switching on The UPS immediately switches on BAT LEVEL bar then it effectuates an initial operating SELF TEST during which the red FAULT and OVERLOAD leds are switched on it switc...

Page 12: ...mode is characterized by The BYPASS led and LINE led switched on The LOAD LEVEL and BAT LEVEL led bars switched on The UPS can be transferred in BYPASS mode even through a manual operation First of a...

Page 13: ...ic signal every second and after it switches automatically to the BYPASS MODE In LINE mode EVO switches automatically to the BYPASS mode as soon as the overload is higher than 150 Once the requested p...

Page 14: ...put line and to the equipment that needs to be powered The UPS is designed to operate in protected environments for example offices This UPS should be installed indoors with adequate airflow and free...

Page 15: ...repeat point 4 and 5 6 Carry out the LOAD TEST according the modalities described in charter LOAD CONTROL Carry out step 3 4 5 6 of the initial start up procedure to change the configuration of the de...

Page 16: ...8 15 minuts AUTONOMY 36 96 96 NOMINAL BATTERY VOLTAGE 3 units 12V 7 2Ah 8 units 12V 7 2Ah 8 units 12V 7 2Ah SEALED MAINTENANCE FREE LEAD ACID BATTERIES TYPICAL BATTERY CHARGE TIME 8 Hours EXPANDABLE A...

Page 17: ...ioning test in BATTERY mode this will preserve the batteries in an excellent state and extend the life duration Leave the UPS in BATTERY mode until the end of autonomy condition is reached After which...

Page 18: ...e UPS OFF and remove the UPS input voltage Check the Input Circuit Breaker Should it be snapped OFF position check if the UPS is overloaded then try to rearm the breaker by bringing it in the ON posit...

Page 19: ...the UPS which are user serviceable Any repair or maintenance work must be performed exclusively by qualified technical personnel authorized by TECNOWARE TECNOWARE declines any responsibility if this...

Page 20: ...19 FIGURES Figure 1 Operating modes UPS EVO 18 User s manual...

Page 21: ...red 2 OFF Button 9 LOAD 100 led blue 10 LOAD 80 led blue 11 LOAD 60 led blue 12 LOAD 40 led blue 13 LOAD 20 led blue Operating modes leds BAT level led bar 3 LINE led blue 14 LOW BAT led yellow 4 BATT...

Page 22: ...aker 3 Grounded output socket 4 Grounded power output socket EVO 2 0 and EVO 3 0 5 Computer Interface RS 232 6 RJ11 RJ45 IN OUT plugs 7 Slot for external batteries connector 8 Dty contacts board Slot...

Page 23: ...and in any case any circumstances in which one cannot date back to the defective manufacture will not be covered by the guarantee Compensation is excluded for direct or in direct damages of any natur...

Page 24: ...TECNOWARE S r l www service tecnoware com...

Reviews: