EVO 304 BASE / EVO BLU BASE
Pag
. 18
29/16
9.
BEFORE REFERRING TO THE TECHNICAL SERVICE
PROBLEM
POSSIBLE CAUSE
REMEDY
The machine does not produce
steam.
Lack of power.
Make sure that the plug (04) is well inserted and
that the main switch of the building is activated.
The red “low water” indicator (11)
lights up.
All the water from the boiler (01) has been
consumed.
Refill the boiler (01) with clean water.
Water
leaks
through
the
connections of the accessories.
Check the wear of the o-rings.
Clean and lubricate the o-rings with grease.
If necessary, replace with the spares supplied.
Steam does not come out.
A) Boiler has not reached yet the operational
pressure (green light (10) is off).
B) Boiler switch (08) has not been activated.
C) Safety switch (13) has not been activated.
A) Wait a few minutes.
B) Activate the “boiler switch” (08).
C) Press the safety switch (13) to activate the
steam flow.
Drops of water come out of the
accessories.
At beginning of work water condenses in the
tubes and accessories due to the difference in
temperature.
After a few minutes of use this problem will
disappear. If it continues, proceed with the boiler
cleaning.
Noise inside the generator.
The boiler getting cold, after about 6-7 hours
creates an internal depression which, at each
ignition, provokes some vibrations.
Wait until the pressure stabilizes (about 2-3
minutes), the noise will disappear.
Steam leaks from the valve cap
(01).
The valve cap (01) is not correctly screwed.
The rubber seal on the valve cap is damaged.
Screw on the safety cap correctly.
Substitute the seal.
Accessories do not fit perfectly.
There is dirt build up in the joints and the
connections.
Clean and lubricate the joints of the accessories.