background image

 

 

EVO 304 BASE / EVO BLU BASE 

 

 

Pag

. 11 

29/16 

 

       FUNCTIONS CONTROL PANEL 

 

 

 

 

 

 

 

 

 

 

 

7. 

OPERATING INSTRUCTIONS 

(a) 

Open the box and eventually block the unit on its cart (optional). 

(b) 

Open the boiler safety cap (01) and add maximum 3 liters of water, 

it is recommended to use 

only  softened  water,  all  other  liquids  can  damage    the  generator  or  make  it  unsafe. 

ATTENTION!! BURNING DANGER!! 

(c) 

Screw on the safety cap (1) until it completely closes. 

NEVER unscrew it during usage.

 

(d) 

Check that there is an earthing system in the electric socket of your home. Insert the plug (04) 

into  an  electrical  outlet,  making  sure  that  the  voltage  and  the  amperage  correspond  to  those 

printed on the plate located under the machine. 

(e) 

Refilling of water: 

Add water only when the machine has cooled down (switched off for at least 5 hours), or when 

the “Low water” indicators light on, as follow: 

-  Remove  the  plug  from  the  power  supply,  unscrew  the  cap  a  turn  and  wait  until  the  steam 

generator has no pressure (all the steam has to come out). 

Only after having verified the absence of pressure it is possible to completely unscrew it.

 

Do  NEVER  completely  unscrew  the  cap  without  having  read  the  instructions,  it  may 

cause serious burns.

 

Presenza vapore

Mancanza acqua

Pulsante a

!

vazione caldaia

Pulsante accensione

Display mul

"

funzione

Multifunction display 

Boiler activation switch 

Power button 

Steam ready indicator 

Low water indicator 

Summary of Contents for ER32060

Page 1: ...EVO 304 BASE EVO BLU BASE Pag 1 29 16 This manual is available in digital format on request kindly contact Info tecnovap it EVO 304 BASE EVO BLU BASE USER INSTRUCTION...

Page 2: ...EVO 304 BASE EVO BLU BASE Pag 2 29 16...

Page 3: ...CONSULT IT LATER OR TO GIVE IT TO THE FOLLOWING OWNERS PLEASE READ THE SAFETY INSTRUCTIONS ON THIS HANDBOOK BEFORE PROCEEDING WITH THE FIRST USE EVENTUAL DAMAGES DUE TO THE TRANSPORT MUST BE COMUNICA...

Page 4: ...TO THE CENTERS SUITABLE FOR THE DISPOSING OF THE WASTE ELECTRIC AND ELECTRONIC EQUIPMENT BATTERIES OIL AND SIMILAR SUBSTANCES MUST BE RECYCLED IN THE PROPER RECYCLING CENTERS AND MUST NOT BE LEFT IN T...

Page 5: ...lve able to ensure the safety of the machine itself in case other primary control devices are inefficient due to a failure Due to the extreme importance of this component and as not to compromise the...

Page 6: ...evice is not intended to be used by persons including children with a reduced physical mental or sensorial ability or with insufficient experience and or competence This unit is not designed to operat...

Page 7: ...04 ER3206I Blu ER32060 Boiler volume L 4 0 Water capacity L 3 0 Rated Voltage V 230 Current type Hz 50 60 Rated Power Boiler kW 2 40 Max Rated Power kW 2 40 Rated Steam Pressure kPa bar 600 6 Permissi...

Page 8: ...n order to have the best performing results This model has a reliable stainless steel boiler which allows to obtain a powerful and steady steam flow Evo 304 Base Evo Blu Base is the ideal solution wit...

Page 9: ...er indicator light 40 Small brass brush 28 41 Small st steel brush 28 12 Steam hose 42 Small triangular brush 13 Safety switch steam outlet 43 Steam plunger 14 Locking lever for steam outlet 44 Steam...

Page 10: ...EVO 304 BASE EVO BLU BASE Pag 10 29 16 6 TECHNICAL DRAWINGS...

Page 11: ...oltage and the amperage correspond to those printed on the plate located under the machine e Refilling of water Add water only when the machine has cooled down switched off for at least 5 hours or whe...

Page 12: ...esired steam flow through the switch 17A on the steam hose at each switching on of the unit the steam selection is always deactivated the led lights on the hose will blink alternatively to indicate th...

Page 13: ...se of washbasin clogging attach the steam plunger 43 to the steam lance 37 and direct the steam into the drain WARNING WHEN USING THE SMALL BRUSHES ON PORCELAIN EXERT THE LEAST POSSIBLE PRESSURE WINDO...

Page 14: ...so that its removal will be easier To spread the wax on the floor use as mentioned above a clean cloth fastened onto the brush Put the wax on the cloth the heat of the steam will help spread the wax e...

Page 15: ...08 on the control panel In this case position the thermostat according to the type of cloth being ironed If the power save mode is activated chapter 7 the device will switch off after 1 hour independ...

Page 16: ...hat minimum 5 hours have been passed after having disconnected the power plug Put a basin under the unit and remove the underlying boiler drain cap 05 wait until the boiler is completely emptied and i...

Page 17: ...h the general power switch 03 Press and keep pressed the buttons 07 and 08 while you keep them pressed switch on the machine again by activating the general power switch 03 8 3 PRESSURE GAUGE With the...

Page 18: ...has not been activated A Wait a few minutes B Activate the boiler switch 08 C Press the safety switch 13 to activate the steam flow Drops of water come out of the accessories At beginning of work wate...

Page 19: ...le specifiche delle direttive conforms to the specifications of directives 2006 95 CE 2004 108 CE 2006 42 CE 2002 95 CE Per il controllo della conformit alle sopraindicate direttive sono stati seguiti...

Page 20: ...EVO 304 BASE EVO BLU BASE Pag 20 29 16 Ordinary maintenance procedures Generator working hours Frequency of intervention Notes...

Page 21: ...EVO 304 BASE EVO BLU BASE Pag 21 29 16 Extraordinary maintenance procedures Generator working hours Intervention Intervention description replaced components etc...

Page 22: ...EVO 304 BASE EVO BLU BASE Pag 22 29 16 NOTES...

Page 23: ...EVO 304 BASE EVO BLU BASE Pag 23 29 16...

Page 24: ...EVO 304 BASE EVO BLU BASE Pag 24 29 16 THE MANUFACTURER RESERVES THE RIGHT TO IMPLEMENT TECHNICAL AND STRUCTURAL CHANGES AND IMPROVEMENTS WITHOUT PRIOR NOTICE...

Reviews: