TECNOVAP CARMEN 3400 User Manual Download Page 8

TECNOVAP

CHATTANOOGA CARMEN

PAG. N.  8

vacuum head (1). Activate the command switch (27) for steam flow and command switch (28)

for vacuum power found on the hand grip.

(h) 

Model 3400:

 The vacuum head (1) is equipped with a floater which stops the air flow when

the  water  has  reached  its  maximum  level  in  the  vacuum  drum  (5).  The  appliance  looses

suction power and there is a change in the noise of the motor.

Model 3400S:

 Also on this model, equipped with a separator, there is a loss in suction power

and a change in the noise of the motor when the water has reached its maximum level in the

vacuum drum (5).

(i)  Turn off the vacuum power switch (2) and unplug the power cord (3). Lift the vacuum head

(1) from the vacuum drum (5) by releasing the latches (6) and empty the drum making sure to

have  detached  the  vacuum  hose  (24)  before.  If  necessary  rince  the  drum  and  refill  it  as

described in step (b) of this section.

(j)  When the red "low water" indicator (14) lights up, turn off the main power switch (13) of the

boiler and unplug the power cord (23) from the main current. Wait until the residual pressure

in the boiler decreases and permits you to remove the boiler cap (17). At this point you can

proceed with refilling the boiler as described in step (a) of this section. 

Warning:

 the boiler

cap, for safety purposes, does not permit removal with pressure inside the boiler.

(k)  Once the cleaning task terminated, it is recommended to vacuum approximatively 4 liters of

clean  water  to  rince  internally  the  flexible  hose  and  the  vacuum  tubes.  Extract  the  vacuum

drum (5) and after having it emptied and rinced, let it dry in a well-aired place.

7.  MAINTENANCE

7.1. 

MAINTENANCE OF THE STEAM GENERATOR

IMPORTANT

-

 

SWITCH  OFF  THE  ELECTRIC  SUPPLY  BEFORE  PROCEEDING  TO  THE  USER'S

MAINTENANCE.

-

 

IT  IS  RECOMMENDED  CLEANING  THE  BOILER  ONLY  WHEN  THE  MACHINE  HAS

COOLED DOWN (FOR AT LEAST 5 HOURS).

ELIMINATION OF SCALE DEPOSITS FROM THE BOILER

We  suggest  cleaning  the  boiler  after  every  200  hours  of  use,  or  also  if  the  machine  produces

water or dirty steam.

Unscrew  the  boiler  cap  (17)  and  fill  with  clean  water.  Position  the  machine  over  a  recipient

container and remove the boiler drain cap (22) located underneath the machine. Pieces of scale

Summary of Contents for CARMEN 3400

Page 1: ...ich allows it to produce a powerful and consistent supply of steam With the power of steam meaning power of ecological cleaning Tecnovap has combined a powerful vacuum able to vacuum solids and liquid...

Page 2: ...TECNOVAP CHATTANOOGA CARMEN PAG N 2 2 TECHNICAL DRAWINGS...

Page 3: ...TECNOVAP CHATTANOOGA CARMEN PAG N 3...

Page 4: ...DATA OF THE VACUUM CLEANER BODY IN PVC CAPACITY 5 5 liters POWER SUPPLY 230 240 V 50 60 Hz VACUUM OUTPUT 400 1200 Watt with electronic power regulator MODEL 3400 WET VAC WITH FLOATER DRUM CAPACITY 4...

Page 5: ...15 Power indicator green 45 Professional steam iron optional 16 Steam flow regulator Min Max 46 Rubber rest pad for iron optional 17 Safety valve cap of the boiler 47 Steam plug of iron 18 Carrying ha...

Page 6: ...N EARTH DEVICE IF NECESSARY THE POWER CORD MAY BE REPLACED ONLY BY AUTHORISED PERONNEL OR SERVICE CENTER FILL THE BOILER WITH CLEAN WATER ONLY DO NOT ADD DETERGENTS OR CHEMICAL PRODUCTS PRESSURE HOSES...

Page 7: ...ose clamping latch 8 has secured the hose coupling and verify that the vacuum switch 2 is in the ON position The hand grip switches 27 and 28 are switched OFF e Activate the main power switch of the b...

Page 8: ...unplug the power cord 23 from the main current Wait until the residual pressure in the boiler decreases and permits you to remove the boiler cap 17 At this point you can proceed with refilling the boi...

Page 9: ...se caused by dirt deposited on the separator unbalancing the alignement of the separator a Unhook the vacuum head 1 from the drum 5 using the latches 6 b Remove the grill protection 10 turning it coun...

Page 10: ...HE C O N N E C T I O N S O F T H E ACCESSORIES CHECK THE WEAR OF THE O RING CLEAN AND LUBRICATE THE O RING WITH GREASE IF NECESSARY REPLACE WITH ONE OF THE SPARES SUPPLIED STEAM DOES NOT COME OUT A BO...

Page 11: ...TECNOVAP CHATTANOOGA CARMEN PAG N 11 10 SOCIETY TECNOVAP 10 1 CERTIFIED QUALITY SYSTEM ISO 9002 10 2 ASSOCIATED AFIDAMP...

Page 12: ...ONAL 4 3 4 TECHNICAL DATA OF THE COMPLETE CARMEN 4 4 NOMENCLATURE 5 5 SAFETY REGULATIONS 6 6 USING INSTRUCTIONS 7 7 MAINTENANCE 8 7 1 MAINTENANCE OF THE STEAM GENERATOR 8 7 2 MAINTENANCE OF THE VACUUM...

Reviews: