TECNOVAP CARMEN 3400 User Manual Download Page 7

TECNOVAP

CHATTANOOGA CARMEN

PAG. N.  7

6.  USING INSTRUCTIONS

OPERATING THE CARMEN WITH THE KIT RADAMES

(a)  Unscrew  the  boiler  cap  (17)  and  fill  the  boiler  with  the  filling  bottle  (19).  The  bottle  holds

approx. 75 cc of water and the boiler capacity is of about 3 liters. Screw on the safety valve

cap (17) correctly.

(b)  Lift  the  vacuum  head  (1)  from  the  drum  (5)  and  clamp  in  place  using  the  latches  (6).  Pour

approx.  1  liter  of  clean  water  in  the  drum  making  sure  that  the  water  level  is  sitting  higher

than the lower part of the internal air intake tube. Reposition the vacuum head (1) onto the

drum (5) and clamp in place using the latches (6).

(c)  Insert the electric plug of the vacuum cleaner (3) into the socket (20) found on the back of the

steam generator. Insert the power cord (23) from your 

CARMEN

 in an electric outlet making

sure that the voltage and amperage correspond to  those found on the rating plate (located

underneath the unit and listed as well in section 3 of this manual). The presence of electrical

power is indicated by the green indicator light (15).

(d)  Insert the steam plug (26) of the Radames steam/vacuum hose into the steam socket (21),

ensuring that the clamping hook (25) correctly locks into place. Then insert the vacuum hose

coupling (24) into the vacuum hose outlet (7) found on the vacuum drum (5). Ensure that the

hose clamping latch (8) has secured the hose coupling and verify that the vacuum switch (2)

is in the "ON" position. The hand grip switches (27 and 28) are switc hed "OFF".

(e)  Activate the main power switch of the boiler (13). Wait approximately 3 minutes for each liter

of  water  added  to  the  boiler  allowing  the  steam  generator  to  reach  operating  pressure.

Operating pressure is reached when the green "ready steam" indicator (12) lights up.

(f)  Your 

CARMEN

 is now ready for use. Choose the accessory best suited for the cleaning task

and connect to the steam/vacuum hose taking particular attention to secure the accessories

with the clamping unit in "BLOK" position (30).

To  clean  with  the  combination  of  steam  and  vacuum  use  one  of  the  following  accessories

most suitable for the task at hand:

Floor tool (31) with ideal insert (33,34,35). The various inserts are locked into place by sliding

the latches (32) to the "OPEN" position and hold the insert in place applying a little pressure

while sliding the latches in "BLOK" position. Remember that the command switches (27 and

28) on the handgrip should be in the "OFF" position.

Turbo lance steam/vacuum (36) to be used by itself or with the small brushes (37-43).

If necessary, attach the extension tubes (29) and lock them in place using the clamping units

(30) in "BLOK" position. It is possible to apply one extension only.

(g)  To  regulate  the  steam  flow  operate  the  steam  ajustment  knob  (16)  found  on  the  steam

generator. To regulate the vacuum air flow operate the adjustment knob (4) situated on the

Summary of Contents for CARMEN 3400

Page 1: ...ich allows it to produce a powerful and consistent supply of steam With the power of steam meaning power of ecological cleaning Tecnovap has combined a powerful vacuum able to vacuum solids and liquid...

Page 2: ...TECNOVAP CHATTANOOGA CARMEN PAG N 2 2 TECHNICAL DRAWINGS...

Page 3: ...TECNOVAP CHATTANOOGA CARMEN PAG N 3...

Page 4: ...DATA OF THE VACUUM CLEANER BODY IN PVC CAPACITY 5 5 liters POWER SUPPLY 230 240 V 50 60 Hz VACUUM OUTPUT 400 1200 Watt with electronic power regulator MODEL 3400 WET VAC WITH FLOATER DRUM CAPACITY 4...

Page 5: ...15 Power indicator green 45 Professional steam iron optional 16 Steam flow regulator Min Max 46 Rubber rest pad for iron optional 17 Safety valve cap of the boiler 47 Steam plug of iron 18 Carrying ha...

Page 6: ...N EARTH DEVICE IF NECESSARY THE POWER CORD MAY BE REPLACED ONLY BY AUTHORISED PERONNEL OR SERVICE CENTER FILL THE BOILER WITH CLEAN WATER ONLY DO NOT ADD DETERGENTS OR CHEMICAL PRODUCTS PRESSURE HOSES...

Page 7: ...ose clamping latch 8 has secured the hose coupling and verify that the vacuum switch 2 is in the ON position The hand grip switches 27 and 28 are switched OFF e Activate the main power switch of the b...

Page 8: ...unplug the power cord 23 from the main current Wait until the residual pressure in the boiler decreases and permits you to remove the boiler cap 17 At this point you can proceed with refilling the boi...

Page 9: ...se caused by dirt deposited on the separator unbalancing the alignement of the separator a Unhook the vacuum head 1 from the drum 5 using the latches 6 b Remove the grill protection 10 turning it coun...

Page 10: ...HE C O N N E C T I O N S O F T H E ACCESSORIES CHECK THE WEAR OF THE O RING CLEAN AND LUBRICATE THE O RING WITH GREASE IF NECESSARY REPLACE WITH ONE OF THE SPARES SUPPLIED STEAM DOES NOT COME OUT A BO...

Page 11: ...TECNOVAP CHATTANOOGA CARMEN PAG N 11 10 SOCIETY TECNOVAP 10 1 CERTIFIED QUALITY SYSTEM ISO 9002 10 2 ASSOCIATED AFIDAMP...

Page 12: ...ONAL 4 3 4 TECHNICAL DATA OF THE COMPLETE CARMEN 4 4 NOMENCLATURE 5 5 SAFETY REGULATIONS 6 6 USING INSTRUCTIONS 7 7 MAINTENANCE 8 7 1 MAINTENANCE OF THE STEAM GENERATOR 8 7 2 MAINTENANCE OF THE VACUUM...

Reviews: