Installation instructions
Pulse
In the locked position the distance between the lock’s bolt and the lock
part that moves the bolt should be approximately 1 mm.
The bolt must be able to move freely without force being applied to it.
The maximum load applicable to the bolt must not exceed 1 KN. Contact Tecnosicurezza in case
of heavier loads.
Connect the keypad cable to the lock connector "1/ENT", making sure it is fully inserted and
locked.
Any alarm interface or battery holder needs to be connected to the lock connector “2/BAT”.
To remove the cable, bring the connector upwards and carefully pull it out.
It’s possible to connect a relocker to the lock cover through the appropriate holes.
DeadBolt and LatchBolt locks installation instructions
DeadBolt and LatchBolt are locks with, respectively, a dead bolt and a spring bolt, whose block
is carried out by a motor.
By entering a valid code, the lock electronic removes the blocking for 3 seconds and the
boltwork can be moved into open position by turning the spindle inserted in the lock.
The spindle can be connected to a knob, a handle or directly to the keypad if equipped with a
rotation kit. In the latter case it must be used the specific rotation kit T3300. When the spindle
is brought to the locked position, the bolt comes out ensuring the lock is locked.
The DeadBolt and LatchBolt locks can be mounted in all four mounting directions (RH, LH, VU,
VD).
Fix the relocker plate with M4 self tapping flat head screws.
Length must be 6 mm + plate thickness.
(i.e. 6 mm + 2 mm plate = 8 mm screw)