II_Pulse_12_eng
13 of 20
Installation instructions
Pulse
Cut the spindle to the correct length (measure door thi mounting plate/rotation knob or
handle lock spindle insert).
Remove any cutting residues of the spindle that could damage the cable.
It’s possible to connect a relocker to the lock cover through the appropriate holes.
T4700/D & T4710/D locks
The spindle needs to be fully inserted inside the lock (7 mm).
Place the cable in the groove of the spindle, making sure it’s fully inserted and locked.
Secure the cable inside the special groove located under the lock
body, ensuring that it is not stretched when turning the spindle.
Fix the lock using the appropriate mounting screws.
Connect the keypad cable to the lock connector "1", making sure it is fully inserted and
locked. Any alarm interface or battery holder needs to be connected to the lock connector
“2”. To remove the cable, bring the connector upwards and carefully pull it out.
EM3520/D & EM3550/D locks
The spindle must be inserted between a minimum of 7 mm to a maximum of 12 mm inside
the lock.
WARNING: do not insert the spindle up to the lid of the lock, but leave some margin to
allow the movement of the cable and to prevent any damage.
Place the cable in the groove of the spindle, making sure it’s fully inserted and locked.
Insert the cable connector into the square hole present in the bottom of the lock and make it
come out from the opposite side.
Secure the cable inside the special groove located on the lock
cover, ensuring that it is not stretched when turning the spindle.
Fix the lock using the appropriate mounting screws.
Connect the keypad cable to the lock connector "ENT", making sure it is fully inserted and
locked. Any alarm interface or battery holder needs to be connected to the lock connector
“BAT”. To remove the cable, bring the connector upwards and carefully pull it out.
Fix the relocker plate with M4 self tapping flat head screws.
Length must be 6mm + plate thickness.