7.4 – FUNCTIONAL DATA

Outputs operating mode: 5 modes for OUT 1: Delayed,
Feedthrough, asymmetric times oscillator with start on or start off
and One cycle Asymmetrical Oscillator Start Off

.

4 modes for OUT 2: like OUT1, ON during count, like OUT1 with
time t3 absolute or relative in advance.
Measurement range: 4 times scales: 9999 hrs., 99 hrs. 59 min., 59
min. 59 sec., 99 sec. 99 cents.
Display  resolution: according to the scale used: hrs., min., sec.,
cents
Overall accuracy: +/- 0,1 % fs
Counting autonomy in case of power failure: 10 hrs. approx. with full
charge battery 
Inputs delay:  15 m sec. Max.
Display: 4 Digit  Red h 14 mm
Compliance: ECC directive EMC 89/336 (EN 61326), ECC directive
LV 73/23 and 93/68 (EN 61010-1)

7.5 – INSTRUMENT CODE

TT 73  a b c d e ff

a : POWER SUPPLY
F

 = 12 VAC/VDC

Y

 = 24 VDC

A

 = 24 VAC

C

 = 110 VAC

D

 = 230 VAC

b : INPUTS
C

 = Free voltage contacts

V

 = Voltage signals (the same voltage supply value).

c : OUTPUT OUT1
R =

 Relay

O =

 12 VDC for SSR

d : USCITA OUT2
R =

 Relay

O =

 12 VDC for SSR

-

 = None

e : INTERNAL BATTERY
-

 = Battery not present

B

 = Battery present

ff = SPECIAL CODES

TECNOLOGIC spa - TT 73

 

- OPERATING INSTRUCTIONS - Vr. 01 - ISTR 06083 - PAG. 7

Summary of Contents for TT 73

Page 1: ...G MODE 4 4 OUT 1 OPERATING MODE 4 3 DISPLAY OPERATING MODE 4 2 COMMANDS OPERATING MODE 4 1 OPERATING MODE 4 ELECTRICAL CONNECTION DRAWING 3 4 ELECTRICAL CONNECTIONS 3 3 MECHANICAL MOUNTING 3 2 USE ALLOWED 3 1 INSTALLATION AND USE ADVICES 3 PARAMETERS LOCK 2 3 PARAMETERS PROGRAMMING 2 2 SET POINT PROGRAMMING 2 1 PROGRAMMING 2 FRONT PANEL DESCRIPTION 1 2 GENERAL DESCRIPTION 1 1 INSTRUMENT DESCRIPTIO...

Page 2: ...dify the Set Point To have again access at the parameters repeat the same procedure pushing key P and selecting uL finally go out from the parameters lock modality 3 INSTALLATION AND USE ADVICES 3 1 USE ALLOWED The instrument has been projected as measure and control device built according to EN61010 1 for the altitudes operation until 2000 ms The use of the instrument for applications not express...

Page 3: ...rior brightness with the purpose to limit as much as possible the absorption from the battery 4 3 OUT1 OPERATING MODE The instrument can be programmed by the parameter F1 to operate in any of the following 5 modes F1 1 DELAYED On receiving the START signal the instrument starts counting time When the set time value t1 has been reached the instrument enables the output OUT1 The output is disabled b...

Page 4: ...ction of delay with the time t3 while if F1 2 or 3 the output OUT 2 operate with the feedthrough function always with the time t3 In the programming mode of the time t3 the display shows t3 i to indicate that the time t3 is independent F2 4 Same function of OUT1 time t1 with time t3 relative to t1 in advance The choice of this mode of operation enable the set t3 that it has the same range time S1 ...

Page 5: ...ing of the CNT EN input the counting is stopped This operating mode is recommended when the user wants to control the timer using voltage signals In fact with an appropriate interface eg an external relay the timer is reset and starts counting when voltage is supplied and stops when voltage is cut off just like a conventional timer In this functioning mode the T frontal key works only as reset 5 P...

Page 6: ...under warranty against construction vices or defected material noticed within 12 months from delivery date The warranty is limited to the repairs or to the substitution of the instrument The eventual opening of the housing the violation of the instrument or the wrong use and installation of the product means the automatic decay of the warranty In case of defected instrument noticed in warranty per...

Page 7: ...uracy 0 1 fs Counting autonomy in case of power failure 10 hrs approx with full charge battery Inputs delay 15 m sec Max Display 4 Digit Red h 14 mm Compliance ECC directive EMC 89 336 EN 61326 ECC directive LV 73 23 and 93 68 EN 61010 1 7 5 INSTRUMENT CODE TT 73 a b c d e ff a POWER SUPPLY F 12 VAC VDC Y 24 VDC A 24 VAC C 110 VAC D 230 VAC b INPUTS C Free voltage contacts V Voltage signals the sa...

Reviews: