4.4 - OUT2 OPERATING MODE
The instrument can be programmed by the parameter
"F2"
to
operate in any of the following 4 modes:
F2 = 1 - Output OUT2 operating like OUT1
The output OUT2 exactly operates like the output OUT1 so that to
be able to have two output contacts.
F2 = 2 - Output OUT2 operating as instant contact
The output OUT2 is activated during the counting phase and
remains activated to the reset command.
F2 = 3 - Same function of OUT1 (time t1) with time t3 absolute:
The choice of this mode of operation enable the set "t3" that it has
the same range time "S1" and cannot be higher of "t1."
Received the start signal the instrument begins the counting and
exactly operating on the output OUT 2 in the same way with which it
operates the function F1 on the output OUT1.
If F1 = 1, 4 or 5 the output OUT 2 operate with the function of delay
with the time "t3" while if F1 = 2 or 3 the output OUT 2 operate with
the feedthrough function always with the time "t3."
In the programming mode of the time "t3" the display shows
"t3 i"
to
indicate that the time t3 is independent.
F2 = 4 - Same function of OUT1 (time t1) with time t3 relative to t1
(in advance) : The choice of this mode of operation enable the set
"t3" that it has the same range time "S1" and cannot be higher of
"t1."
Received the start signal the instrument begins the counting and
exactly operating on the output OUT 2 in the same way with which it
operates the function F1 on the output OUT1.
If F1 = 1, 4 or 5 the output OUT 2 operate with the function of delay
with the time [”t1” - "t3"] while if F1 = 2 or 3 the output OUT 2
operate with the feedthrough function always with the time [”t1” -
"t3"].
In the programming mode of the time "t3" the display shows
"t3 d"
to indicate that the time t3 is dependent.
If “F2” = 0 the output OUT 2 is always disabled.