GB / IE - 1
5410.424.00
Part 1
Installation
PYROCERAMIC INDUCTION HOB
General Instructions
The appliance referred to in this manual has been manufactured in
conformity to the following Directives: 73/23/EEC, 93/68/EEC “Low
Voltage”; 89/336/EEC, 92/31/EEC, 93/68/EEC and EN55014
“Electromagnetic Compatibility.
The appliance must be installed by a qualified technician according to
the regulations and directives in force in the country where it is installed,
as well as the instructions in this manual. This appliance has been
designed exclusively for cooking food. Remove the packaging from the
appliance as well as the protective plastic sheet, and, if necessary,
remove traces of glue with a suitable solvent. To dispose of the
packaging, follow local directives.
When installing the appliance, the following regulations must be
observed:
Applicable national laws in force;
Regional and/or local regulations, such as building codes;
Directives and regulations of the local electricity board;
Accident prevention regulations in force;
Fire prevention regulations;
Applicable I.E.C. regulations.
To use the appliance correctly follow the warnings below:
The appliance must never be left unattended when it is being used!
The appliance is designed for professional use and therefore should
only be used by qualified personnel.
Care must be taken when using the appliance because the cooking
surfaces are very hot.
The appliance should be installed under an extractor fan for
removing cooking fumes.
If the appliance is installed in line:
Respect a minimum distance of 80mm between the appliance and
any walls made of flammable material, partitions, kitchen furniture or
nearby equipment.
The surfaces in contact with the appliance must be covered with
non-combustible heat insulating material.
The appliance, and especially the power lead, must not be installed
anywhere near heat sources.
The temperature of the environment in which the appliance is
installed must not rise above 50°C.
Switch the appliance off in the case of a failure or malfunction.
Connection to the distribution network
Before connecting the appliance note the specifications necessary for
the installation: voltage, frequency, number of phases and power on the
data plate of the appliance.
The adhesive polyester data plate is behind the control panel
“T” fig.2.
The installer must make the connection after having installed a main
switch, which is easy to reach and disconnects every pole supplying
electrical power to the appliance. The switch supplying electrical energy
to the appliance must have a minimum distance of at least 3mm
between the poles when the contacts are open.
THE CABLE:
Must not be installed near heat sources, the ambient temperature of
the surrounding environment must not rise to over 50°C.
Must be protected by a rigid metal or plastic tube
Must at least meet H07 RN-F standards.
Must have the minimum section indicated in the table fig.1.
To reach terminal board “M” fig.2, remove the control panel by loosening
the screws on the lower part of the panel. Following the indications in
the wiring diagram, connect the wires of the power cable to the terminal
board. The appliance must be connected to a good earth. There is a
screw marked with the symbol near the terminal board where the
earth conductor should be connected. Hold the cable in place until you
can block it with cable clamp fig.1. The appliance must be connected
to a good earth. The appliance must also be connected to an
equipotential earth. Connect the earth with the screw marked on the
rear panel of the. The equipotential wire must have a section of 10mm
2
.