1.5 POSITIONING AND FEET REGULATION
Place the Multideck Display in a perfect horizontal position, acting if
necessary on the screw type adjustable feet. Use a spirit level to check it. The
Multideck Display must be placed in order to operate properly and allow the
correct defrost condensate water draining. In this way you will avoid noisy
vibrations of the condensing unit. Check the correct positioning of the con-
densate water basin and its draining.
1.6 INSTALLATION INSIDE YOUR SHOP/RESTAURANT /WORKROOM
The equipments are tested in test-room with ambient temperature of +25°C and relative humidity
60%, therefore, if the ambient in which the equipment is installed has different conditions of ambient temperature
and relative humidity, it could be verifi ed a malfunction and the equipment will not run properly (making inside
condensation….etc). It is advisable to install the equipment inside an area with an air conditioning system. Please
note that malfunctions may arise in areas that are not provided with air conditioning, e.g. condensation formation.
ATTENTION
In order to allow a good functioning of the
equipment
please pay attentions to the following instructions:
•
Do not place the unit in an area directly exposed to sun light or to other heating sources, such as high
intensity incandescent lighting systems, ovens or other radiant heating sources, e.g. heating radiators etc.
•
Do not place the unit nearby door openings producing air currents, whether doors or windows
or directly exposed to air from fans, vents or fan coil unit air conditioner.
•
Do not block or obstruct the air inlets of the built-in refrigeration unit.
•
Do not place any objects on the unit, including boxes or any other type of objects; leave the entire
perimeter of the unit completely free so that air can circulate properly.
•
Do not place the equipment inside areas with high relative humidity levels (it may cause forma-
tion of condensation)
•
Do not place the equipment inside a closed niche, as there is not enough air circulation and may
cause the refrigeration unit to not work properly.
•
Do not place the unit one above another.
•
Verify that the room in which the equipment is placed must be suffi ciently aired, even when the shop is closed.
Verify that in the installation room there is enough air turnover, even during closing and rest hours. In
this way the expansion/condensing unit will work correctly.
1.7 WATER CONDENSATION DRAIN WATER DRAIN CONNECTION
The Multideck Display with built-in unit is fi tted with automatic evaporating water condensation
tank with sponge. Verifi ed that the water pipe is correct positioned and periodically and the basin is must be
cleaned from waste materials.
The Multideck Display with remote unit, not having the basin for water collection is provided with
a siphon only, the customer take care of the water connection pipe. Its connection to the principal basin pre-
vents the circulation of cold air and of bad smells. The Multideck Display cannot absolutely be installed
without siphon and each drain must have its own siphon. It is necessary to have the drain-siphon after the
exit of belly section to block the out-take air and also to avoid any smell. You never install the Multideck Display
without siphon and to connect more drains of the same Multideck Display together. Each drain must have
only one siphon.