background image

IST-2210.IC01.01 

Istruzione / User’s Manual / Manuel d’utilisation 

Pag.1/8

 

(IST-2210.IC01.01_TS210IC2_Anidride Carbonica (16.12.2015).docx)

 

 

Trasmettitore IR di CO

2

 con uscita 4÷20mA 

IR CO

2

 Gas Detector with 4÷20mA output 

Sonde IR a transmetteur 4÷20mA pour gaz 

CO

2

 

 

 

 

TECNOCONTROL S.r.l. - Via Miglioli, 47 20090 SEGRATE (MI) ITALY 

Tel. +39 02 26922890 - Fax +39 02 2133734 

http: 

www. tecnocontrol.it

 

e-mail:

 

[email protected]

 

 

 

TS210 IC2 

 

 

 

 

Leggere Attentamente e Conservare quest’Istruzione. 

Please read and keep this manual 

Lire avec soin et garder la notice d’instruction 

 

Per cinque anni non è necessario effettuare la calibrazione del sensore. 

For five years it is not necessary to calibrate the sensor. 

Pendant cinq ans, ne est pas nécessaire d'étalonner le capteur. 

 

Modello

 / Model / Modele  

Calibrato per

 / Calibrated for / Tarée pour

 

TS210 IC2

 

Anidride carbonica

 / 

Carbon Dioxide / dioxyde de carbone

 

 

 

 

 

Caratteristiche tecniche / 

Technical specifications

 / 

Caractéristiques techniques

 

Alimentazione / 

Power supply 

/

 Alimentation

 

12÷24Vcc (

-10/+15%

) 2W / 

12÷24Vdc (

-10/+15%

) 2W

 

Sensore / 

Sensor Type 

/

 Capteur

 

NDIR 

(Nondispersive Infrared Sensor)

 

Uscite /

 Outputs 

/

 Sortie

 

4 ÷ 20 mA lineare /

 Linear 

/

 linéaire

 

Resistenza di carico /

 load resistor 

/

 résistance de charge

 

50 ohm / 12Vdc (

-10%

) - 500 ohm / 24Vdc (

-10%

Campo di misura / 

Standard Range 

/

 Champ de mesure

 

0 ÷ 2 % vol (

=20000 ppm

Vita media in aria / 

Average Life in air 

/

 Vie moyenne en air

 

MTBF (

Sensore / Sensor

 

/

 Capteur) 

> 5 anni

 

/

 years 

/

 ans

 

Tempo di risposta / 

Response Time

 / Temps de réponse  

60s < T

90 

< 105s (dipendente dal valore misurato /

 depend-

ing on the measured value / dépend de la valeur mesurée

)

 

Ripetibilità di zero / Zero 

Repeatability 

/

 Zéro répétitivité

 

±1% FS (Fondo Scala / 

Full Scale / fond d’échelle

)

 

Precisione /

 Accuracy 

/

 Précision

 

±0,02%vol (

=200ppm

) + 5% del valore misurato 

/ of measuring value / de la valeur mesurée 

Tempo di Preriscaldo / 

Warm up time 

/

 Temps de préchauffage

 

< 60 sec - Funzionamento / 

operational 

/

 fonctionnement

  

< 5 min - a specifiche / Full 

specification

 / 

Stabilité

 

 

Risoluzione / R

esolution 

/

 résolution

 

0,01 %vol (

=100 ppm

Linearità /

 Linearity 

/

 Linéairite

 

± 1.5% FS 

Deriva a lungo termine in aria 

Long time drift

 

in air 

/

 Dérive à long terme en air

 

0,002%vol (

=20 ppm

) anno / 

year 

/

 an

 

Tempo massimo di immagazzinamento 

Max Storage Time 

/

 Temps maximum de stockage

 

1 anno

 

/

 

year 

/

 an

 

Temp./umidità di immagazzinamento / 

Storage Temp-Humidity 

Température et hygrométrie de stockage

 

-40 ÷ +60°C / 5÷95 % RH 

non condensata / 

non condensed 

/

 non condensée

 

Temp./umidità di funzionamento /

 

O

peration Temp./Humidity 

Température et hygrométrie de fonctionnement

 

-20 ÷ +55 °C / 10÷90 % RH 

non condensata / 

non condensed 

/

 non condensée

 

Pressione / 

Operation Pressure

 / 

Pression

 

de fonctionnement

 

85 ÷ 110 kPa 

Grado di protezione -Dimensioni – Peso / 

IP Code - Size – 

Weight / Indice de protection - Dimensions du boîtier - poids

 

IP44 / 160 x 80 x 67 mm / 400g 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

IT

 

 DESCRIZIONE ................................................................................................................................... 2

 

NOTE SUI VARI MODELLI .......................................................................................................................... 2

 

FUNZIONAMENTO ...................................................................................................................................... 2

 

INSTALLAZIONE ......................................................................................................................................... 2

 

AVVERTENZE .............................................................................................................................................. 3

 

VERIFICHE ................................................................................................................................................... 3

 

EN

 

 DESCRIPTION ................................................................................................................................... 3

 

NOTES ON THE AVAILABLE MODELS ..................................................................................................... 4

 

OPERATIONAL DESCRIPTION .................................................................................................................. 4

 

INSTALLATION ............................................................................................................................................ 4

 

WARNING .................................................................................................................................................... 4

 

TESTS .......................................................................................................................................................... 5

 

FR

 

 DESCRIPTION ................................................................................................................................... 5

 

NOTES SUR LES DIFFERENTS MODELES ............................................................................................... 5

 

FONCTIONNEMENT .................................................................................................................................... 6

 

AVERTISSEMENTS ..................................................................................................................................... 6

 

VERIFICATIONS .......................................................................................................................................... 7

 

Summary of Contents for TS210 IC2

Page 1: ...ta Response Time Temps de réponse 60s T90 105s dipendente dal valore misurato depend ing on the measured value dépend de la valeur mesurée Ripetibilità di zero Zero Repeatability Zéro répétitivité 1 FS Fondo Scala Full Scale fond d échelle Precisione Accuracy Précision 0 02 vol 200ppm 5 del valore misurato of measuring value de la valeur mesurée Tempo di Preriscaldo Warm up time Temps de préchauff...

Page 2: ... gas mentre il rivelatore di riferimento fornisce il valore di zero La differenza di segnale tra i due rivelatori fornisce il valore di concentrazione di gas Il vantaggio di questa tecnica è che è selettiva soprattutto per gas come l anidride carbonica che è difficile da misurare con altri sistemi ed inoltre ha il vantaggio di compensare i cambiamenti che si verificano nella sensibilità del rileva...

Page 3: ...so complete di valvola d erogazione inoltre è necessario usare il kit di prova Tecnocontrol mod TC011 oppure TC014 TEST ELETTRICO Codice Test F2 F2 F1 F1 permette di effettuare un test funzionale del rilevatore Dopo aver messo l impianto in sicurezza ed aver inserito il Codice Test si spengono tutti i LED e si accenderanno in se quenza dal giallo al rosso L uscita 4 20mA rimane invariata Alla fine...

Page 4: ...etect gas even if it attains the optimum stability con ditions after about 10 30 minutes continual functioning only after this time can be made the calibration check Normal operation the green LED ON should be light on Alarm when the gas concentration exceeds the value indicated in the table the red LED illuminates only if it be activate by Dip Switch no 4 set to ON TS210 IC2 0 25 vol CO2 Faults t...

Page 5: ...d can be made after the installation But it should be done during the periodic maintenances to verify the effective functioning of the detector NOTE please use the gas mixture as indicated above Normally it is sufficient to perform the Calibration check with gas 1 Volume CO2 Cylinder in nitrogen but you can also carry out Checking Zero Pure Zero Air Cylinder Insert the TC011 TC014 over the sensor ...

Page 6: ...capteur La led jaune est allumée et la verte est éteinte sortie 0mA cet état indique plusieurs possibilités de dérange ments 1 la configuration des Dip Switch n est pas correcte vérifier la position Voir Tableau 2 2 le capteur est en panne panne du capteur ou communication absente ou incorrecte Faire les vérifications couper puis rétablir l alimentation de l appareil Si les conditions persistent s...

Page 7: ...se correcte au gaz en utilisant en fonction du type de sonde le mélange indiqué ci avant Elle peut être effectuée après l installation mais elle est surtout destinée aux essais durant les maintenances périodiques afin de vérifier le bon fonctionnement de la sonde NOTA utiliser le mélange de gaz comme indiqué ci dessus Normalement il suffit d effectuer la Vérification de l éta lonnage Bouteille de ...

Page 8: ...pport à l air Gas più pesante dell aria Gas heavier than air gaz plus lourd que l air Fig 1 Dimensioni Size Dimensions Fig 2 Schema di collegamento Wiring diagram Schéma S 12 24V mA 1 2 3 4 ON OFF SET Test Uscita Output Test Sortie Test 40 200mV TESTmV 12 24Vdc Alimentazione Power Supply Alimentation Centrale rivelazione gas Gas Central Unit Centrale de détection RL S S Uscita 4 20 mA 4 20 mA Outp...

Reviews: