The manufacturer cannot be held liable for accidental or indirect damages should the device be modified,
repaired without authorization or should any of its component be damaged due to accident or misuse.
Any minimal modification / repair on the device voids the warranty and does not guarantee the compliance with
the technical requirements provided by the MDD 93/42/EEC (and subsequent changes) and its normatives
CONTRAINDICATIONS
-
Before using the KYRI DSS, consult the instructions for use: failure to read all the instructions in this manual can be harmful
for the patient.
-
The device cannot be used to drain chest fluids;
-
The device must not be used for suction of explosive, corrosive or easily flammable liquids.
-
KYRI DSS is not suitable for MRI. Do not introduce the device in MRI environments.
TECHNICAL CHARACTERISTICS
TYPOLOGY (MDD 93/42/EEC)
Class IIa Medical Decice
MODEL
KYRI DSS
UNI EN ISO 10079-1
HIGH VACUUM / HIGH FLOW
POWER FEEDING
230V~ / 50Hz
POWER CONSUMPTION
385 VA
FUSE
F 1 x 4A L 250V
MAXIMUM SUCTION PRESSURE (without jar)
-90kPa / -0.90 Bar / -675mmHg
MAXIMUM SUCTION FLOW (without jar)
90 l/min
WEIGHT
20 Kg
SIZE
460 x 850 (h) x 420 mm
DUTY CYCLE
Non – Stop Operated
SICILICONE TUBE SIZE
Ø 8 x 14 mm
ACCURANCY OF VACUUM INDICATOR
± 5%
WORKING CONDITION
Room temperature: 5 ÷ 35°C
Room humidity percentage: 30 ÷ 75% RH
Atmospheric pressure:
800 ÷ 1060 hPa
Altitude: 0 ÷ 2000m s.l.m.
CONSERVATION CONDITION AND TRASPORT
Room temperature: -40÷ 70°C
Room humidity percentage: 10 ÷ 100% RH
Atmospheric pressure:
500 ÷ 1060 hPa
WARRANTY CONDITIONS
This product is guaranteed for a period of 24 months from the date of purchase. The warranty includes the repair or replacement of
defect spare parts free of charge, if the defect has been clearly described by the customer and determined by technical service.
Inspections on the part of the seller, performed at the request of the customer and intended to determined wjether the device is fully
functional, are not covered by the free-of-charge warranty service. This service will be charged to the customer depending on the
effort required. The consumables components are not subject to warranty. Consumable components are silicon tubes, filters, seals,
conical adaptor and suction catheter. Also exluded from warranty is all damage resulting from improper handling, wilful damage or
improper care of the device. The warranty shall expire if repairs and servicing are not carried out by technical service.
RULES FOR RETURNING AND REPAIRING
UNDER NEW EUROPEAN RULES, TECNO-GAZ REQUIRES THE FOLLOWING PROCEDURES TO BE CARRIED OUT TO PROTECT THE
INSTRUMENT AND THE SAFETY OF ALL WHO COME IN CONTACT WITH IT.
Before returning an instrument for repair, the external surfaces and all accessories
MUST
be carefully disinfected with a cloth
soaked in methylated spirits or hypochlorite-based solution. The instrument and accessories should then be placed in a bag with a
note outlining the disinfection undertaken.
Failure to follow this procedure will result in the instrument being returned to the purchaser unrepaired.
Instruments returned for repair
MUST
be accompanied by a description of the problem. TECNO-GAZ will not be responsible for
damage caused through improper use. To avoid such damage, please read the instruction carefully.
Where TECNO-GAZ determines that an instrument is faulty, a replacement will be provided only if a SALES RECEIPT and STAMPED
GUARANTEE are provided. TECNO-GAZ will not be responsible for damage accessories. These may be replaced at the customer’s
expence.
Summary of Contents for KYRI DSS
Page 1: ...I 1 ...
Page 48: ...48 ...