T011S ver. tS2111
www.tecnoautomazione.com
Pag. 2 / 17
INPUT FUNCTIONS
PIN
INPUT
Go
Start
–
oP
Open –
CL
Close –
Po
Dead man open –
PC
Dead man close –
Eo
Domus–
EL
electric-lock
1
8
E1
no
disabled
-
St
Stop –
oP
open –
CL
close
2
8
E2
no
disabled -
tC
external photocell logic 1
–
td
external photocell logic 2
3
8
E3
no
disabled
-
tA
internal photocell -
EL
Electric-lock
4
8
E4
no
disabled -
FC
closing limit switch N.C. -
LC
closing limit switch N.O.
5
8
E5
no
disabled
-
FA
opening limit switch N.C.
LA
opening limit switch N.O.
6
8
E6
PE
Pedestrian
–
oP
Open –
CL
Close –
Po
Dead man
open –
PC
Dead man close –
Eo
Domus –
EL
electric-lock
7
8
E7
BOARD’S
COMPONENTS
A
Button A
B
Button B
C
Button C
D
Button D
F1
250 VAC power fuse 5A
F4
Resettable fuse 24V 1.6A
F5
Resettable fuse 24V 0.6A
A B C Ground terminals
CN
Primary varistor
V1
Secondary varistor
V2
Terminal block pins
1 to 20 Button A
RESETTABLE FUSE
AFTER A SHORT-CIRCUIT:
•
TURN OFF THE
CONTROL BOARD.
REMOVE THE SHORT-
CIRCUIT.
•
WAIT FOR 60
SECONDS OR MORE.
TURN ON THE
CONTROL BOARD.
F4/F5
INPUTS CONNECTION
OUTPUTS CONNECTION
DOMUS
Multi functions module (optional)
ELSER
12 Volt Electric lock module (optional)
MOTORS
CLOSE
COMMON
OPEN
Motor A
13
14
15
FLASHING LAMP 24V 20W
24VDC 300 mA
11
12
8
+
10
-
PHOTOCELLS
24 VDC
TYPE
PIN
INPUT
+
-
EXTERNAL
(closing)
TX
9
10
E3
RX
8
10
Normally
Closed
3
8
INTERNAL
(opening)
TX
9
10
E4
RX
8
10
Normally
Closed
4
8