T-44/48 Series Amplifier
Operation Manual
T-44/48 Series | rev.
firm. 1.258 and above
48
An inbuilt alarm and notification system can be configured to indicate problems to remote devices either
via the network or the Volt-free changeover relay contacts accessibly on the rear panel.
Physical
Cooling
Variable speed fans.
Airflow
Front to back.
Air filtration
Washable media, changeable without the use of
tools.
Analog IN and LINK connectors
Genuine Neutrik XLR.
AES3 IN and LINK connectors
Genuine Neutrik XLR.
Audio output connector
Genuine Neutrik Speakon.
Mains input connector
Genuine Neutrik 32A Powercon.
Dante Primary and Secondary
Shielded RJ45.
Relay output & contact closure inputs
Phoenix pluggable terminal block.
Front panel display (backlit)
Graphical, high contrast, daylight visible.
Front panel encoders
Two, indented, velocity sensitive.
Front panel push buttons
Large, tactile, illuminated.
LED indicators
Bright, easily differentiated. Enclosure Standard
19” 2U (88mm) with handles and optional rear
support system
Depth (behind rack ears)
357mm (14”).
Net Weight
12.5kg (27.5 pounds).
Power Output
Model
T20-44
T10-44
T06-44
Power specification
RMS output power per channel, all channels driven with continuous program material
and a nominal ambient temperature of 40degC / 105degF
Crest Factor of 4 (12dB), 2-Ohm nominal load
5,000W
2,500W
1,500W
Crest Factor of 2.8 (9dB), 4-Ohm nominal load
3,000W
2,500W
1,500W
Crest Factor of 2 (6dB), 8-Ohm nominal load
1,500W
1,500W
750W
Bridged, per channel pair, 4 Ohm load
10,000W
5,000W
3,000W
25V line (CV) operation, Crest Factor 4 (12dB)
1250W
885W
685W
70V line (CV) operation, Crest Factor 4 (12dB)
3500W
2,500W
1,500W
100V line (CV) operation, Crest Factor 4 (12dB)
5,000W
2,500W
1,500W
Model
T10-48
T06-48
T03-48
Power specification
RMS output power per channel, all channels driven with continuous program material
and a nominal ambient temperature of 40degC / 105degF
Crest Factor of 4 (12dB), 2-Ohm nominal load
1,250W
750W
400W
Crest Factor of 2.8 (9dB), 4-Ohm nominal load
1,250W
750W
400W
Crest Factor of 2 (6dB), 8-Ohm nominal load
1,250W
750W
400W
Bridged, per channel pair, 4 Ohm load
2,500W
1,500W
800W
25V line (CV) operation, Crest Factor 4 (12dB)
625W
485W
355W
70V line (CV) operation, Crest Factor 4 (12dB)
1,250W
750W
400W
100V line (CV) operation, Crest Factor 4 (12dB)
1,250W
750W
400W
Options
TECNARE can supply for digital audio network a Dante option card for T-44/48 Series amplifier
to be factory fitted. Currently Tecnare support Dante from Audinate.