6
U
SE
6.1
Operation instruction and electrical panel settings
The mixing machine is controlled by a electrical panel with internal CPU, that will generate the signal / input
to the agitation motor. The control panel is located in the right shoulder of the machine.
START BUTTON
Enables to start the motor in the cyclical function
based on the setted time (default: 20 min. ON, 240
min OFF)
STOP BUTTON
Stops the motor and the cyclical function.
EMERGENCY BUTTON
Will stop the motor, but will maintain the electrical
panel powered. To restart the motor and the cyclical
function, turn the emergency button clockwise, and
press the start button.
LiGHT INDICATION
Green Led
=
Dispenser powered ( tension present )
Red Led flashing and Green Led off
= Motore in rotazione e macchina in fase di agitazione
Red and Green Led fixed light
= Cycle mode active ( agitation motor off ready to start )
Note:
To restart the motor during the pause period, press the red STOP button, wait a few seconds
and press the green START button.
Led
Green
Led
Red
Start
Stop
Emergency