GB
programming 29
Subject to technical modifications without prior notice.
TP-40.1-12/4
Messages by LEDs
Message
LED 1 red (TL)
LED 2 yellow
LED 3 green
LED 4 red (TF)
Control unit ready after being switched on (mains switch)
Off
Off
Off
10 x blinking
If there is an integrated radio receiver
Off
Off
Off
blinking
Menu item “Learn travel path and power” is displayed
Off
On
Off
Off/blinking
Menu item “Learn travel path and power” activated
Off
blinking
Off
Off/blinking
In the process of learning travel path and power
Off
On
Briefly activated Off/blinking
Force cut off due to obstacle hit during movement
On
Off
Off
Off/blinking
Start button OR 1st channel of hand-held transmitter activated Off
Off
On
Off/blinking
2nd channel of hand-held transmitter for
day light/partial opening
Off
Off
Off
On
Interruption caused by emergency stop
On
Off
Off
Off/blinking
Interruption caused by light barrier
On
Off
Off
Off/blinking
Error Messages
LED 1 red (TL) LED 2 yellow Recommended
Learning travel path and power not ok
4 x Blinking
Off
Repeat process
(emergency light blinks 10 times)
Error message related to the security feeds
Permanent light
Off
Check on the security feeds
including emergency stop
Autotest light barrier
Permanent light
Blinking
Only deadman operations possible until repaired
Autotest safety distance
Permanent light
Permanent light
Only deadman operations possible until repaired
EEPROM data missing
4 x Blinking
Off
Repeat travel path and power learning process
EEPROM damaged
Blinking
On
PCB blocked, Briefly disconnect mains plug
Relays damaged
Blinking
Blinking
PCB blocked, Briefly disconnect mains plug
Drive motor damaged
2 x Blinking
Off
Contact customer service
Electric circuit faulty
2 x Blinking
On
Only deadman operations possible until repaired
Attention!
Error messages on the display can be erased only by switching off and turning back on the power supply
(pulling the mains plug).
Attention! Before connecting or disconnecting any supplementary modules, receivers,
counters or jumpers, switch off the power supply and pull out the plug!
Instant stop - input potential-free = 8
Instant stop - output potential-free = 7
Light barrier jumper = 6
Light barrier jumper 0 V earth = 5
24 V DC unstable / 80 mA = 4
Start/stop 0 V earth = 2
Start/stop push-button potential-free = 1
24 V DC unstable / 80 mA = 3
TS
TL
TF
ZM
1 2 3
ON
Connection receiver (Molex 10 pol.)
ZM
max. 230 V AC
max. 120 W
1
7 6 5 4 3 2
9 8
-
+
8,2 kOhm +/- 5%
1
7
65
43
2
9
8
-
+
TL = pushputton learn
TS = pushputton start
LED1 learn red
LED2 force yellow
LED3 start green
K = without function
Green light
max. 230 Vac - 120 W
Warning lamp - Red light
max. 230 Vac - 120 W
DIP-Switch see above
N°3- ON Light barrier on
Function DIP- Switch
N°1- OFF Automatic closure off
N°1- ON Automatic closure on
N°2- OFF Short partial opening
N°2- ON Complete partial opening
N°3- OFF Light barrier off