TECHWOOD TCL-12003 Instruction Manual Download Page 27

  27 

Product Information 

 

Supplier name 

TECHWOOD 

Model identifier 

TCL-12003 

 

 

 

Rated value 

Measured value 

Capacity for cooling 

3,50 kW 

3,420 kW 

Capacity for heating 

N/A 

N/A 

Power input cooling 

1,37 kW 

1,303 kW 

Power input for heating 

N/A 

N/A 

Energy efficiency ratio 

2,6 

2,62 

Coefficient of performance 

N/A 

N/A 

 

 

 

Power consumption in off-
mode 

N/A 

Power consumption in 
standby mode 

0,44 W 

Electricity consumption of 
single/double duct 
appliances (indicates for 
cooling and heating 
separately) 

Q

SD

:1,303 kWh/h for cooling 

 

Sound power level 

65,0 dB(A) 

Global warning potential 

3 kgCO

2

 eq. 

Contact details for obtaining 
more information 

Sotech International 33 av du Maréchal de Lattre de Tassigny 94120 
Fontenays-sous-Bois - France 

 

Product Fiche 

 

Supplier name 

TECHWOOD 

Model identifier 

TCL-12003 

 

 

Sound power level 

65,0 dB(A) 

Refrigerant 

R290 / 245g 

Global Warming Potential : 3 kgCO 

2

 eq. 

Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential 
(GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the 
atmosphere. This appliance contains a refrigerant fluid with a GWP equal to (3). This means that if 1 
kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 3 
times higher than 1 kg of CO

2

, over a period of 100 years. Never try to interfere with the refrigerant 

circuit yourself or disassemble the product yourself and always ask a professional. 
Energy efficiency 

Class A 

Hourly electricity 
consumption 

Q

SD

: 1,4 kWh/60 minutes for cooling 

 
 
Energy consumption 1,4 kWh per 60 minutes, based on standard test 
results. Actual energy consumption will depend on how the appliance is 
used and where it is located. 

Cooling capacity 

3,5 kW 

Heating capacity 

N/A 

Contact details for obtaining  Sotech International 33 av du Maréchal de Lattre de Tassigny 94120 

Summary of Contents for TCL-12003

Page 1: ...use in order to avoid damage due to incorrect use and to better understand the functions of this product Please pay particular attention to the safety guide If you pass the device on to a third party...

Page 2: ...shower wash hand basins or other containers with water Never use this apparatus near water projections Never use this apparatus with the wet hands If unfortunately the apparatus is wet immediately wit...

Page 3: ...ages Never use the appliance if cord or appliance shows any signs of damage Never immerse the appliance in water or any other liquid for any reason whatsoever Never place it into the dishwasher Never...

Page 4: ...do not come in contact with water Before cleaning always unplug the appliance from the power supply and let it cool down This appliance is not intended to be operated by means of an external timer or...

Page 5: ...ut this type of repair GENERAL INFORMATION The symbol OPEN BOOK means a recommendation to read important things contained in the record The symbol BIN crossed out abbreviation WEEE Waste of Electrical...

Page 6: ...ignite easily in contact with a flame or spark or under the influence of heat and take all precautions accordingly The symbol TRIMAN indicates that the consumer is invited to dispose the product as p...

Page 7: ...e case of flammable refrigerants shall not be installed in an unventilated space if that space is smaller than 11 8m2 Compliance with national gas regulations shall be observed Mechanical connections...

Page 8: ...industry recognised assessment specification Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel s...

Page 9: ...a shall be instructed on the nature of work being carried out Work in confined spaces shall be avoided The area around the workspace shall be sectioned off Ensure that the conditions within the area h...

Page 10: ...eyed to make sure that there are no flammable hazards or ignition risks No Smoking signs shall be displayed Ventilated area Ensure that the area is in the open or that it is adequately ventilated befo...

Page 11: ...ently resistant to being corroded or are suitably protected against being so corroded Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks a...

Page 12: ...e to cables excessive number of connections terminals not made to original specification damage to seals incorrect fitting of glands etc Ensure that the apparatus is mounted securely Ensure that seals...

Page 13: ...nder no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks A halide torch or any other detector using a naked flame shall not be used Leak...

Page 14: ...system both before and during the brazing process Removal and evacuation When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used Howe...

Page 15: ...s available Charging procedures In addition to conventional charging procedures the following requirements shall be followed Ensure that contamination of different refrigerants does not occur when usi...

Page 16: ...ndling refrigerant cylinders all personal protective equipment is available and being used correctly the recovery process is supervised at all times by a competent person recovery equipment and cylind...

Page 17: ...linders ensure that only appropriate refrigerant recovery cylinders are employed Ensure that the correct number of cylinders for holding the total system charge are available All cylinders to be used...

Page 18: ...correct recovery cylinder and the relevant waste transfer note arranged Do not mix refrigerants in recovery units and especially not in cylinders If compressors or compressor oils are to be removed en...

Page 19: ...ventilation grille 4 Casters 5 Air inlet 7 Air inlet 8 Air outlet 9 Drainage nozle 10 Air inlet grid 11 Remote control 12 Vent pipe for hot air 13 Adjustable sealing plate the window Connectable to th...

Page 20: ...the timer Press both up and down keys simultaneously to change temperature in Fahrenheit degrees or Centigrade Celsius degrees 5 Mode key Press the key to select Cool Vent Dry 6 Timer button A Press t...

Page 21: ...sealing plate is adjustable Notes It is important to keep the air duct the most linear possible Avoid being bent Incorrect installation will affect the work of the air conditioner Ensure that air can...

Page 22: ...the speed Sweet or Strong Fan mode By pressing the Mode key 2 it is possible to select the Ventilation mode Press either the remote control or the control panel the ventilation indicator lights up Pr...

Page 23: ...by mode press the Timer key to set the activation time Press the Up and Down keys to set the activation time 1 24H The timer indicator lights up In on mode press the Timer key to set the stop time Pre...

Page 24: ...de after cleaning STORAGE Ensure the unit is completely cool and dry Do not wrap the cord around the appliance as this will cause damage Keep the appliance in a cool dry place SEASONAL CLEANING winter...

Page 25: ...ts of the apparatus or the accessories rising from a defect of materials or manufacture by repair or replacement The services within the framework of the guarantee do not involve any extension of the...

Page 26: ...cian for repairs This apparatus satisfied EC directives it was controlled according to all the European current directives like electromagnetic compatibility EMC and low tension LVD This apparatus was...

Page 27: ...0 245g Global Warming Potential 3 kgCO 2 eq Refrigerant leakage contributes to climate change Refrigerant with lower global warming potential GWP would contribute less to global warming than a refrige...

Page 28: ...28 more information Fontenay sous Bois France...

Reviews: