background image

 

 

2.3 Installation of Brackets. 

2.3.1 Wall Mounted 

   

                                                Fig 1 

Installation conditions: 

Wall mounted dome can be used in the hard wall structure whose thickness should be enough 
to install expansion bolt in indoor and outdoor environment. The wall can bear at least 4 times 
the weight of the dome. Install wall hanging bracket: 

a. As shown in fig 2, with the installation holes in the underside of the wall hanging bracket as 
pattern, draw punched locations and punch. 

 

Fig 2 

b. As shown in fig 3, fix the wall hanging bracket on the wall with wire and cable through it. 

 

Fig 3 

Summary of Contents for Z-HA2PS6SW18

Page 1: ...2MP Mini 18X PTZ Z HA2PS6SW18...

Page 2: ...flash with arrowhead symbol within an equilateral triangle is intended to alert the user the presence of non insulated dangerous voltage within the product s enclosure that maybe of sufficient magnit...

Page 3: ...e or disassemble any internal parts of the video camera to avoid normal operation and possibly void the warranty There are no serviceable parts inside the camera All electrical connections to the dome...

Page 4: ...maged in any way when liquid traces are present or the presence of loose objects is evident or if the device does not function properly or has received sever impact or has been dropped accidentally 11...

Page 5: ...2 4 Ceiling Mounted 11 2 3 Installation of Brackets 12 2 3 1 Wall Mounted 12 2 3 2 Corner Mounted 13 2 3 3 Pole Mounted 14 2 3 4 Ceiling Mounted 15 2 4 Connection 16 3 Function Instruction 17 3 1 Powe...

Page 6: ...Clean Transparent Cover 28 Appendix Common Knowledge on RS 485 Bus 28 1 Basic Feature of RS 485bus 28 2 Mode of Connection and Terminal Resistance 28 Appendix Exception Handling 29 Copyright Statement...

Page 7: ...1 Product Introduction 1 1 Package Contents IR Speed dome 1pc Wall mount bracket 1pc Power supply 1pc Screws kits 1pc User manual 1pc...

Page 8: ...ard Tours 3 groups Guard Points Max 16 points dwell time user selectable Home Pos Time 1 60mins available PWR on Action Restore as power up Pan scan A B scan Park action Guard tour group 1 3 No action...

Page 9: ...neon lamp etc 4 Targets are behind the glass covered with water droplets or dust 5 Targets are moving quickly 6 Monotonous large area targets such as wall 7 Targets are too dark or faint BLC If a brig...

Page 10: ...en preset is called Guard Tours Dome patrol scans according to certain edited preset order Power Off Memory This feature allows the dome to resume its previous preset or status after power is restored...

Page 11: ...In order to avoid losses of cable causing low voltage and keep the dome work properly when processing wiring please refer to the requirement below Cable diameter 0 5mm 20 1 0mm 18 1 5mm 16 2 5mm 14 D...

Page 12: ...2 2 2 Corner Mounted Bracket 2 2 3 Pole Mounted Bracket 2 2 4 Ceiling Mounted...

Page 13: ...expansion bolt in indoor and outdoor environment The wall can bear at least 4 times the weight of the dome Install wall hanging bracket a As shown in fig 2 with the installation holes in the undersid...

Page 14: ...the dome Install corner mounted attachment and wall hanging bracket a As shown in fig 12 with the installation holes in the corner mounted attachment as pattern draw punched locations on the wall with...

Page 15: ...and outdoor environment whose diameter should match the installation size of stainless hose clamps Factory default is 6 inches stainless hose clamps fit 130 152mm pillar The pole structure can bear a...

Page 16: ...can be used in the hard ceiling structure whose thickness should be enough to install expansion bolt in indoor and outdoor environment The ceiling can bear at least 4 times the weight of the dome Ins...

Page 17: ...aying surface of the base of hang ceiling and the ceiling board and around the out holes to be sure water proof c As shown in the fig 21 tighten the boom with electrical wire and cable through it on t...

Page 18: ...utton to make the lens closer and magnify the scene Focus Press FOCUS button close shot will become clearer while long shot will become fuzzy Press FOCUS button long shot will become clearer while clo...

Page 19: ...low table for details Remark Please do not change the parameter of the Sub OSD menu randomly to avoid any unexpected happen Please reboot the PTZ after switch the video signal output 3 3 Shortcut comm...

Page 20: ...nt Right Enter the option select the item or confirm Left Return to main menu or cancel Angle Display XXX XX pan XXX XX tilt IR Display Display on the lower right corner of the screen Remark 1 Items w...

Page 21: ...4 OSD Menu 4 1 Menu Index...

Page 22: ...the product upgrading TEMPERATURE Display the temperature of the camera it changes along with the temperature of the camera the data is unchangeable by manual Remark Protocol ID and COMM all can be s...

Page 23: ...unication setting is enable 4 3 2 IR Display WORKING MODE IR Working mode has auto black white color selectable Default is auto TESTING TIME On IR auto working mode and the programmed time the IR will...

Page 24: ...The number of the preset is from 0 64 but 0 is not valid Dwell time is 1 to 60s selectable Speed is 1 to 64 grade selectable INIT After initial preset point dwell time and speed will resume to defaul...

Page 25: ...guard tour 02 guard tour 03 and Preserve action When park mode is OFF status the dome doesn t run park mode When park mode is PRESERVE ACTION status it records previous action order A B scan Pan scan...

Page 26: ...to stop it set mask to OFF status If the module doesn t support privacy mask the screen will display the interface as Fig 4 3 7 3 4 3 8 Alarm Optional ALARM Alarm has OFF and ON selectable PATROL TIME...

Page 27: ...iper speed 1 5 level adjustable WIPER TIMES Wiper times 1 5 times adjustable OTHERS Set other options 4 4 Camera CAM Display the information of module supported by this dome ZOOM SPEED Zoom speed is q...

Page 28: ...nt action such as A B scan Call preset Save preset Call park action Pan scan etc User can enable or disable it IR IR is ON and OFF selectable DOME ID At the top left corner of screen it displays the d...

Page 29: ...s used in the area which opened and steel pipe units grounded in one point Overhead wiring is absolutely prohibited In the strong thunderstorms area or areas with high induced voltage such as high vol...

Page 30: ...rt is serious user can use a mild detergent Any senior furniture cleaning products can be used to clean the under cover Appendix Common Knowledge on RS 485 Bus 1 Basic Feature of RS 485bus According t...

Page 31: ...Set the correct protocol baud rate and address of dome device Improper connection of control cable polarity Verify the polarity of the RS485 connection as per the instruction manual Noise after self t...

Page 32: ...Therefore the company reserves the right to modify or improve the products described in this manual without notice The content of manual is offered according to the current state Unless applicable law...

Reviews: