Installing the VP-II Scanner     

The VP-II Scanner must be installed in a place  where it will not be 
exposed to direct sunlight. Reflected sunlight may interfere with the 
system,  as  well.  High  humidity,  rain,  and  excess  dust  may  interfere 
with  the  functioning  of  the  VP-II  system;  install  the  Scanner  away 
from such elements. 

Do not install the VP-II Scanner where the floor is inclined. 

Install the VP-II Scanner at a height of 1015-1045mm from the floor 
and  100mm  from  the  doorframe.  If  there  is  a  wall  beside  the  door, 
VP-II Scanner should be at least 200mm apart from the wall. 

 
 
 
 
 
 
 
 
 
 
 

 

 

 

Put  the  bracket  on  the  place  for  installing  the  VP-II  Scanner  and 
make  a  hole  after  checking  the  hole  location  for  cabling.  Fix  the 
bracket on the wall using the bracket screws.     

Power  must  be  applied  only  after  finishing  all  connections.  Do  not 
perform any disconnection or connection after power is applied. 

1015~1045mm 

Door

    

100mm 

200mm 

Floor 

Wall 

Summary of Contents for VP-II M

Page 1: ...Installation Guide VP II M Hand Vascular Pattern Recognition System The Second Generation...

Page 2: ...served Techsphere Co Ltd makes no warranty for the use of its products assumes no responsibility for any errors that may appear in this document and makes no commitment to update the information conta...

Page 3: ...II M system is installed improperly the system may not function properly Symptoms of improper installation range from complete operation failure to lowered system performance In order to connect a VP...

Page 4: ...I Scanner 5 Chapter 3 Installing the VP II Controller 7 Chapter 4 Connecting to a door lock optional 9 Chapter 5 System configuration 10 Chapter 6 Connecting the VP II Converter 12 Chapter 7 Preparing...

Page 5: ......

Page 6: ...verify that all of the items pictured below are included in your VP II M package VP II scanner RJ 45 cable switch mode power supply SMPS User s guide two 2 RJ 45 connectors seven 7 screws VP II contro...

Page 7: ...ere the floor is inclined Install the VP II Scanner at a height of 1015 1045mm from the floor and 100mm from the doorframe If there is a wall beside the door VP II Scanner should be at least 200mm apa...

Page 8: ...nner on the bracket Make sure that the scanner fit into the bracket all the way in You may need some force When the scanner is fixed turn the security lock key clockwise and then fix the scanner brack...

Page 9: ...a place where access for maintenance is convenient Ensure that a power outlet is near Make a hole in the wall for affixing the controller then insert a screw approximately two thirds of the way in Fix...

Page 10: ...ler set the dip switch of the VP II Controller as shown below For extension to a network environment multiple Scanners and multiple Controllers see the VP II NCU installation guide Factory setting Sin...

Page 11: ...to an electronic door lock as shown below Maximum rating of the relay contact in the system is DC 24V and 1A N C N O COM Relay N C N C N C N C COM N O N O N O N O reserved Option Door open push type T...

Page 12: ...installed as shown in the figure on the right Use the 4 meter connection cable provided by Techsphere to connect the VP II Scanner and the VP II Controller The length of the connection cable should no...

Page 13: ...Classification of connection cables RS 422 RJ 45 Connectors Using the VP II Repeater Not using the VP II Repeater host PC VP II Scanner VP II Converter host PC VP II Scanner VP II Controller VP II Con...

Page 14: ...r the VP II Controller and the host PC is shown in the following figure For the RS 232 cables use the cables provided by the Techsphere To extend the connection cable see the VP II Converter installat...

Page 15: ...es the RJ 45 connectors are used To prepare a connection cable apply connection in a straight through manner between the two RJ 45 connectors as follows 8 brown 8 7 brown white 7 6 blue 6 5 blue white...

Page 16: ...tem accordingly Determine whether verification performance is good If the system is connected to a door lock ensure that the lock is functioning as intended If the system is connected to a host PC thr...

Page 17: ...resentative if any component of the VP II M system emits smoke or unusual odors Do not disassemble repair or modify the VP II M system Contact your Techsphere local sale representative for such work D...

Page 18: ...representative We can help with any matter relating to the evaluation purchase and use of VP II Hand Vascular Pattern Recognition systems including providing general information explaining ordering pr...

Page 19: ...stalled and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interfere...

Page 20: ...Wonil B D 4F 980 54 Bangbae Seocho Seoul Korea 137 060 TEL 82 2 523 4715 Fax 82 2 523 4765...