52
Figure 3-1
In the first line, from
the left to the right,:
1
,
2
,
3
,
4
,
5
,
6
,
7
,
8
,
9
,
10
,
11
,
12
,
13
,
14
,
15
,
16
ALARM 1 to ALARM 16. The alarm becomes active in low voltage.
In the second line,
from the left to the
right:
NO1 C1
,
NO2 C2
,
NO3 C3
,
NO4 C4,
NO5 C5 NC5
The first four are four groups of normal open activation output (on/off
button)
NO5 C5 NC5 is a group of NO/NC activation output (on/off button)
CTRL 12V
Control power output. For external alarm, you need to close the
device power to cancel the alarm.
+12V
It is external power input. Need the peripheral equipment to provide
+12V power (below 1A).
Earth cable.
485 A/B
485 communication port. They are used to control devices such as
decoder.
T+,T-,R+,R-
They are four-wire double duplex RS485 port
T+ T-: output wire
R+ R-: input wire
3.6.2 Alarm Input Port
Please refer to the following sheet for more information.
Grounding alarm inputs. Normal open or Normal close type)
Please parallel connect COM end and GND end of the alarm detector (Provide
external power to the alarm detector).
Please parallel connect the Ground of the DVR and the ground of the alarm detector.
Please connect the NC port of the alarm sensor to the DVR alarm input(ALARM)
Use the same ground with that of DVR if you use external power to the alarm device.
Summary of Contents for HYBDVR-FE016-DH-160 Hybrid Serie
Page 21: ...40...
Page 106: ...128 Figure 4 90 Figure 4 91...
Page 107: ...129 Figure 4 92 Figure 4 93...
Page 113: ...135 Figure 4 98 Figure 4 99...
Page 114: ...136 Figure 4 100 Figure 4 101...
Page 117: ...139 Figure 4 105 Figure 4 106...
Page 130: ...152 Figure 4 125 Figure 4 126...
Page 198: ...220 Figure 5 68 Figure 5 69 Please refer to the following sheet for detailed information...
Page 252: ...274...