Annex A SPN of MasterCAN DAC Functional modules / Analog Gateway FM
MasterCAN DAC J1939 i/o modules. Operation manual. Version 2.0
©
Technoton, 2018
57
A.6 Analog Gateway FM
is designed to convert signals of the
compliance with the user settings:
•
for input channels it receives analog signals, converts them into digital values of
SPN
parameters and and transfers them into
CAN j1939/S6 Telematics interface
•
for output channels it receives digital
data via CAN j1939/S6 Telematics
paramaters into analog signals of different types (voltage,
frequency, current, discrete, resistive) and transfers them into the Unit respective
physical outputs.
*
This FM is created only for MasterCAN DAC2113 model.
Figure A.8
—
Window of settings of Analog Gateway FM in Service S6 MasterCAN software
Table A.6
—
Analog Gateway FM.
SPNs, displayed and/or editable in Service S6 MasterCAN software
SPN
Name
Factory
value
Unit of
measure
Range
Clarification
Channels list (
Array
elements
count
No
pc.
0…34
Total number of adjustable channels for MasterCAN DAC2113.
MasterCAN DAC2113 has 34 channels altogether
(of them 21 input channels, 13 output channels.)
Channel
number
No
No
1…34
Select the number of the MasterCAN DAC2113 channel which is
to be configured from the list of channels of the Unit.
Each channel number has its specifications:
1) channel physical design (“input/output”):
- channels numbered from 1 to 21 are physical inputs
(designated
);
- channels numbered from 22 to 34 are physical outputs
(designated
).
2) Input/output connector and numbers of contacts for
electrical connection.