Annex C SPN of CAN UP 27 Functional modules
CAN UP 27 online telematics gateway. Operation manual. Version 1.0
© Technoton, 2017
63
Table C.9 — Collector 1A1F1D FM. Displayed and/or editable SPN with the help of
Software Service CAN UP
SPN
Name
Factory
value
Unit of
measure
Range
Clarification
Inputs Settings
(
PGN 63100
)
521364
Input Number
No
No
No
Select I1 group of contacts of analog physical input of
CAN UP27.
521150
PGN
65258
Vehicle weight
No
0…65535
Enter output PGN, which will contain SPN parameter
converted from analog signal.
PGN can be selected through Service software from the
list, containing most important Vehicle parameters, or
from the extended S6 DB list.
1214
SPN
582
Axle weight
No
0…524287
Select SPN, which should be resulted from converting
analog signal.
521188
S6 Address
(SA)
100
No
0…255
Enter unique network address (SA) of CAN UP 27
connected via S6.
SA cannot be edited if PGN is sent ―on request‖.
521362
PGN Sending
Period
0
ms
0…4294970000 Enter time interval (in ms) of sending generated PGN
via S6.
For ―on request‖ sending, enter 0 ms.
Calibration Table Input 1
(
PGN 63101
)
521365
Physical input
type
Analog
V
0…30
Select ―analog‖ type of physical signal input from the
drop-down list.
A user can disable ―analog‖ type of input. In this case,
all the input settings will not be available for editing.
521366
Signal input
value
0; 30 V
On the fact 0…4294970000 Analog input values are saved as points of the calibration
table for input 1. By default, the table contains two points
corresponding to extreme values of the range in which
input signal is changing. Maximum of 10 calibration points
can be saved.
In the software, after pressing "Graph" button, you will
see a graph displaying in accordance with calibration
table a relation between converted SPN parameter
values and input signal level (see figure C.3).
521347
SPN value
0; 30000 kg
On the fact 0…4294970000 Converted SPN parameter values are saved as points of
the calibration table for input 1. By default, the table
contains two points corresponding to extreme values of
the range in which parameter is changing. Maximum of 10
calibration points can be saved.
In software window, you will see current value and chart
of converted SPN parameter change in real time
(see figure C.2).
Inputs Settings
(
PGN 63100
)
521364
Input Number
No
No
No
Select I2 group of contacts of frequency physical input of
CAN UP27.
521150
PGN
61444
Electronic
engine
controller 1
No
0…65535
Enter output PGN, which will contain SPN parameter
converted from frequency signal.
PGN can be selected through Service software from the
list, containing most important Vehicle parameters, or
from the extended S6 DB list.
1214
SPN
190
Engine speed
No
0…524287
Select SPN, which should be resulted from converting
frequency signal.
521188
S6 Address
(SA)
100
No
0…255
Enter unique network address (SA) of CAN UP 27
connected via S6.
SA cannot be edited if PGN is sent ―on request‖.
521362
PGN Sending
Period
50
ms
0…4294970000 Enter time interval (in ms) of sending generated PGN
via S6.
For ―on request‖ sending, enter 0 ms.