Annex C SPN of CAN UP 27 Functional modules
CAN UP 27 online telematics gateway. Operation manual. Version 1.0
© Technoton, 2017
55
SPN
Name
Factory
value
Unit of
measure
Range
Clarification
521063
High Voltage
Level
1.29
-
0…1.99
Field for entering value of high voltage level of onboard
network (1.29▪U
nom
) (see figure C.1).
Entered value of voltage is used as a threshold for recording
"Faulty ON" Event.
521064
Generator
Voltage
Level
1.16
-
0…1.99
Field for entering value of voltage level of generator, i.e.
when engine of Vehicle is running (1.16▪U
nom
)
(see figure C.1).
521065
Engine
Starter
Voltage
Level
0.91
-
0…1.99
Field for entering value of voltage level starter is running, i.i
when Vehicle’s engine is starting (0.91▪U
nom
)
(see figure C.1).
521067
Low Voltage
Level
0.75
-
0…1.99
Field for entering value of low voltage level of ON
(0.75▪U
nom
). Entered value of voltage is used as a threshold
for recording "Faulty ON" Event.
(see figure C.1).
521068
Battery Off
Level
0.20
-
0…1.99
Field for entering value of voltage level when ON switches
off (0.20▪U
nom
).
(see figure C.1).
521074
Engine
Starter
Continues
Working
Time Limit
30
s
5…30
Field for entering value of starter’s permissible time of
continuous operation, above which the starter may fail
(see figure C.1).
Entered value is used as a threshold for recording
"Exceeding permissible time of continuous operation of
starter" Event.
Vehicle power supply. Counts
PGN 62976
521173
Vehicle
hours of
operation
on power
supply
On the fact
s
0…4211080000 Counter of total operating time of Vehicle from onboard
network since CAN UP 27 installation to the Vehicle. User
cannot reset the value of this counter
*
.
521172
Vehicle
hours of
operation
from battery
On the fact
s
0…4211080000 Counter of total operating time of Vehicle from
accumulator since CAN UP 27 installation to the Vehicle.
User cannot reset the value of this counter
*
.
521170
Starter
hours of
operation
On the fact
s
0…4211080000 Counter of total operating time of starter since CAN UP 27
installation to the Vehicle. User cannot reset the value of
this counter
*
.
521171
Starter
hours of
operation
On the fact
s
0…4211080000 Counter of total operating time of Vehicle’s engine since
CAN UP 27 installation to the Vehicle. User cannot reset
the value of this counter
*
.
*
Counter can be reset by the
Manufacturer
of
RSC
.
4)
Battery FM
— designed for power supply status check, built-in battery condition and total
CAN UP 27
operation time from the battery.
Table C.4 — Battery FM. Displayed and/or editable SPN
with the help of Software Service CAN UP
SPN
Name
Factory
value
Unit
of measure
Clarification
Battery
PGN 63086
521129
Unit power
status
On the fact
No
Current power-supply status of CAN UP 27:
- powered from embedded power source;
- powered from on-board electrical system;
- power is off;
- power-supply status is not available/not supported by this device.
While working with service software, data exchange between PC and
CAN UP 27 is possible only if Unit is power-supplied from external source
and power-supply status of CAN UP 27 will always be displayed as
―powered from on-board electrical system‖.