Assembly Instruction for the KBS Pew Heat-Radiator
Insulation board mounting
The insulation board can be mounted directly onto wood in most cases (if load-bearing
surface). Mount the insulation board between the bottom of the sitting surface and the
heater. See diagram page 4! For good appearance, mount the printed side of the
insulated board facing the wood. You can mount the insulation board with nails or with
staples. For both ways of mounting make sure the nails or staples are long enough (at
least 20 mm). Do not drive the nails or staples through the wood to avoid creating holes.
If you use nails, make sure the nailhead is big enough (at least 4 mm). Do not use less
mounting points than indicated in the table. After mounting the insulated board, mount
the heater in the middle.
Type
Sizes [W x L x H]
mm
Minimum number of
fastening points
Suitable devices
UPK 6/3
600 x 250 x 3
9
KBS 6/25
UPK 8/3
800 x 250 x 3
12
KBS 8/35
UPK 10/3
1000 x 250 x 3
15
KBS 10/45
UPK 12/3
1200 x 250 x 3
(two parts)
21
KBS 12/55
UPK 14/3
1400 x 250 x 3
(two parts)
24
KBS 14/65
Data:
Type:
UPK 3
Installation:
stationary
Area of application:
in churches acc. to DIN 4701
Surface:
Mineral fibre, similar to RAL 1013 pearl white
Classification temperature:
800°C
thermal conductance:
0.13 (W/mK) at 400°C
Breakdown voltage:
10 kV (average)
Thickness:
3 mm
6. After-sales service
Your electric heating device was carefully manufactured and checked repeatedly before
dispatch. If you should nevertheless encounter a problem or have questions concerning
handling, feel free to contact us.
Lucht LHZ Elektroheizung GmbH & Co. KG
Obere Hauptstr. 61
09232 Hartmannsdorf, Germany
Ph. ++49 3722 63370
Fax: ++49 3722 633720
E-mail: [email protected]
web: www.technotherm.de
TECHNOTHERM After-sales service:
Ph. ++49 911 93 78 32 10
GB