Assembly Instruction for the KBS Pew Heat-Radiator 

 

Electrical installation 

Only authorised electricians may install and mount the bench heaters. 

 

1)  Fastening / cover 
2) 

Cable gromme

t

 

3)  Clamp 
4) 

Fastenin

g

 

5)  Steatite piece 
6)  Quartz heating element 
7)  Aluminium reflector/ mirror 

 

 

 

Remove the cover grid and mount the heater under the sitting surface (in the middle of 
the bench). Mount the supply line on the bottom of the bench and lead it in on the front 
side of the heater. The heaters are wired-through at 1.5 mm. 

Should several heaters be mounted on one bench, one heater can be plugged into the 
one opposite and fed into the next one. Heaters up to a total load of 3000 Watts can be 
connected in series. The TECHNOTHERM church bench heater boasts a chromium-
nickel steel heating element.  
 
The advantage: non-brittle and non-corrosive! After the electrical instalment, remount 
the cover grid from below with the lock washer and the screw. The heaters have to be 
completely (all poles) disconnectable from the mains power supply by using switches, 
contactors or automatic disconnecting devices at a minimum distance of 3 mm between 
contacts. Make sure the phase load is even. Use an electronic thermostat with variable 
continuous contact for controlling. Install a heating time limit (set to 6 h) and a timer to 
automatically start the heater.  
We will gladly provide circuit diagrams tailored for your project listing the electrical 
controls used. 
 

 

 

 

 GB 

Summary of Contents for KBS 6/25

Page 1: ...5 KBS 8 35 KBS 10 45 KBS 12 55 KBS 14 65 Assembly and Operating Instructions Pew Heat Radiator KBS GB 2 3 Please read attentively and keep in a safe place Subject to alterations Issue 07 16 Id_no 911...

Page 2: ...n under the age of 3 are to be kept away unless they are continually supervised Children between the age of 3 and 8 are only allowed to switch the heater on or off if they are supervised or given inst...

Page 3: ...ter Area of application In churches acc to DIN 4701 max room temperature is 15 C Test mark Surface powder coated similar to RAL 1090 Distances Minimum distance to combustible material 80 mm from the f...

Page 4: ...ther two heaters parallel to each other under one bench If there is a danger of damage on painted benches or crack formation in damp wood mount a non flammable insulation board UPK between the heater...

Page 5: ...o the next one Heaters up to a total load of 3000 Watts can be connected in series The TECHNOTHERM church bench heater boasts a chromium nickel steel heating element The advantage non brittle and non...

Page 6: ...tor Electrical installation Wiring diagram Heater installation may only be performed by an expert in accordance with the wiring diagram Pay strict attention to the latest electrical safety standards a...

Page 7: ...le Type Sizes W x L x H mm Minimum number of fastening points Suitable devices UPK 6 3 600 x 250 x 3 9 KBS 6 25 UPK 8 3 800 x 250 x 3 12 KBS 8 35 UPK 10 3 1000 x 250 x 3 15 KBS 10 45 UPK 12 3 1200 x 2...

Reviews: