17/04/2019
–
TPF-Eco version u111
•
rF04
–
Remove wireless associations (from thermostat only.)
o
See “
How to connect your panels
” for full guide.
1G
–
Configuration Menu
All customisable settings can be found here. The menu takes you through each setting in turn. Use
+/- keys to adjust settings, press OK to confirm and move onto next setting.
See
above
for how to reach configuration menu.
•
CF01
–
Correcting the measured temperature
o
This allows you to manually adjust for any discrepancy between the temperature
read by the thermostat and the actual temperature in the room.
o
Use +/- keys to adjust from -5 °C to 5 °C.
▪
i.e. if the thermostat senses 24 °C but the actual temperature is 20 °C, set
CF01 to -4 °C to adjust down.
•
CF02
–
Temperature displayed in auto mode
o
0 = Set temperature (default)
o
1 = Actual temperature
•
CF04
–
Thermostat control type
o
0 = Chrono-proportional (PI) control (default)
▪
Thermostat checks temperature at time intervals and then tells heaters to
turn on/off.
o
1 = On/Off control
▪
Thermostat tells heaters to turn on/off as soon as it detects the temperature
dropping below/above the set level.
•
CF05
–
Display energy saving settings
o
0 = Display switches off after 10 seconds if nothing is pressed
o
1 = Displays switches off between midnight and 5am
o
2 = Display always on (default)
•
CF06
–
On/off symbol displayed in standby mode
o
0 = Not displayed
o
1 = Display (default)
•
CF07
–
Backlight
o
0 = Disabled
o
1 = Enabled (on when using thermostat, switches off after a timer) (default)
•
CF08
–
Open window detection function
o
0 = Disabled (default)
o
1 = Enabled
o
NOTE
–
this function only works if you have paired the thermostat with a
door/window magnetic contact which tells the thermostat it has opened.
•
CF09
–
Presence detection function
o
0 = Disabled (default)
o
1 = Enabled
o
NOTE
–
this function only works if you have paired the thermostat with a motion
detector
o
If your motion detector senses absence, it will do the following after set periods of
absence:
▪
1.5 hour -> Temperature of current setting is reduced by -1.5 °C
▪
3.5 hour -> Temperature of current setting is reduced by -3.5 °C