Technosoft 2021
39
iPOS360x HX-CAN Technical Reference
3.7.17 CAN-Bus
Min.
Typ.
Max. Units
Compliance
ISO11898, CiA-301v4.2, 402_2v4.1
Bit rate
Software selectable
250
1000
Kbps
Bus length
1Mbps
40
m
500Kbps
100
≤ 250Kbps
250
Resistor
Between CAN-Hi, CAN-Lo
none on-board
Node addressing
Hardware ( CANopen selection pin)
127 (CANopen);
255 (TMLCAN);
Software
1 - 127 (CANopen); 1- 255 (TMLCAN)
Voltage, CAN-Hi or CAN-Lo to GND
-36
36
V
ESD protection
Human body model
±15
kV
3.7.18 Supply Output (+5V)
Min.
Typ.
Max. Units
+5V output voltage
Current sourced = 350mA
4.8
5
5.2
V
+5V output current
iPOS360X HX-CAN
250
500
540
mA
Short-circuit protection
Yes / Drive resets at event
Over-voltage protection
NOT protected
ESD protection
Human body model
±1
kV
3.7.19 Conformity
EU Declaration
2014/30/EU (EMC), 2014/35/EU (LVD),
2011/65/EU (RoHS), 1907/2006/EC (REACH),
93/68/EEC (CE Marking Directive),
EC 428/2009 (non dual-use item, output frequency limited to 590Hz)
†
Stresses beyond values listed under “absolute maximum ratings” may cause permanent damage to the device. Exposure to absolute-maximum-rated
conditions for extended periods may affect device reliability.