background image

TS Enclosure 530 User Manual 

Rev. 1.

2

 

TS-ENC530 - 7

 

 

Enclosure TS-530 Ethernet Port 

 

 

Ethernet

: The Ethernet connector is a standard RJ-45 socket. It can be used to connect a 

standard 10baseT Ethernet cable into the enclosed EPC.  

 

Enclosure TS-530 COM1 Port 

 

 

COM1:  

COM1 is brought in from the enclosed SBC. This 9-pin SubD connector is 

industry standard for a PC. The TxD, RxD, RTS, CTS, and ground pins are supported for 

RS-232 communications.  

See the table below for RS-485 operation. 

COM1 9-Pin SubD Outs Table 

 

Half Duplex RS-485

 

RS-232

 

Full Duplex RS-485

 

9-Pin 

SubD 

Signal 

9-Pin 

SubD 

Signal 

9-Pin 

SubD 

Signal 

1

1

 

 

RX/TX +  

1

1

 

 

 

1

1

 

 

TX + 

2

2

 

 

 

2

2

 

 

Receive data 

2

2

 

 

 

3

3

 

 

 

3

3

 

 

Transmit data 

3

3

 

 

 

4

4

 

 

 

4

4

 

 

 

4

4

 

 

RX + 

5

5

 

 

Ground 

5

5

 

 

Ground 

5

5

 

 

Ground 

6

6

 

 

RX/TX -  

6

6

 

 

 

6

6

 

 

TX - 

7

7

 

 

 

7

7

 

 

Request to Send 

7

7

 

 

 

8

8

 

 

 

8

8

 

 

Clear to Send 

8

8

 

 

 

9

9

 

 

 

9

9

 

 

 

9

9

 

 

RX - 

 

 

 

Summary of Contents for TS-ENC530

Page 1: ...Enclosure TS 530 User Manual 16525 East Laser Drive Fountain Hills AZ 85268 TEL 480 837 5200 FAX 480 837 5300 info embeddedx86 com http www embeddedx86 com...

Page 2: ...Technologic Systems Inc TS ENC530 2 COPYRIGHT 1998 200...

Page 3: ...p Procedure 5 Disconnecting AC Power 5 Components 6 Standard Headers and Connectors 6 Front Panel 6 Rear Panel 6 COM1 9 Pin SubD Outs Table 7 COM2 9 Pin SubD Outs Table 8 Product Specifications 10 Dim...

Page 4: ...gulator efficiently converts 12 38 VDC to regulated 5 VDC required by the SBC COM ports adapted to standard 9 pin Sub D Status LED s for Ethernet port are visible Power Good LED visible on the rear pa...

Page 5: ...al material handling Set the enclosure on a level surface with adequate ventilation Ensure the rubber feet are used for protection and stability on level surfaces Wall mount the unit if placement on a...

Page 6: ...losure 530 Rear Panel Connectors The rear panel of the metal enclosure has four connectors and two additional elements as indicated in the above view Identifiers and a description for each are listed...

Page 7: ...pin SubD connector is industry standard for a PC The TxD RxD RTS CTS and ground pins are supported for RS 232 communications See the table below for RS 485 operation COM1 9 Pin SubD Outs Table Half Du...

Page 8: ...RS 232 9 Pin SubD Signal 1 1 2 2 Receive data 3 3 Transmit data 4 4 5 5 Ground 6 6 7 7 Request to Send 8 8 Clear to Send 9 9 Enclosure TS 530 12 38 VDC Connector 12 38VDC The three pin connector accep...

Page 9: ...closure 530 User Manual Rev 1 2 TS ENC530 9 Chassis Grounding Lug The lug labeled with the chassis ground symbol is used to ground the chassis optional Note Connect this to earth ground during install...

Page 10: ...intain the operational environmental specifications listed in the table below Environmental Specifications Standard Temp Products Extended Temp Products Ambient Temperature 0 60 C The internal tempera...

Page 11: ...TS Enclosure 530 User Manual Rev 1 2 TS ENC530 11 Options and Other Features RS 485 is optional on COM1 A wall mounted power supply is available for this product...

Page 12: ...ions of operation or attempts to alter or modify the function of the product i Important This warranty is limited to the repair or replacement of the defective unit In no event shall Technologic Syste...

Page 13: ...ipment does cause interference which can be determined by turning the unit on and off the user is encouraged to try the following measures to correct the interference 1 Reorient the receiving antenna...

Page 14: ...Technologic Systems Inc TS ENC530 14 Appendix A Enclosure Views Enclosure TS 530 Front Top View Enclosure TS 530 Rear Panel View...

Page 15: ...User Manual Rev 1 2 TS ENC530 15 Appendix B User Manual Revisions Date of Issue Revision Revision Number Comments July 2004 July 2008 June 2009 1 2 Updated mailing address 1 0 1 1 First release Fixed...

Page 16: ...Technologic Systems Inc TS ENC530 16 16525 East Laser Drive Fountain Hills AZ 85268 TEL 480 837 5200 FAX 480 837 5300 info embeddedx86 com http www embeddedx86 com...

Reviews: