JOG NOW : Service & maintenance manual - rev. 5.1
Page 4.2
4.2.
PC LINK FOR PROGRAMMING
The machine can be connected to a PC for programming by means of the RJ45 connector on the C-
Safe board.
The cable to use must be wired as follows:
ATTENTION: for the numbering of the pins, on RJ45 connector, please refer to the
diagram below:
When programming the machine sometimes it is necessary to fit plug into the free RJ-45
port on the back of the display, to avoid any type of interference during the operation.
The wiring diagram of the RJ-45 plug is as follows:
Programming cable and plug can be ordered using the code
R0002534AC
.