62
DEVELOPMENT, MANUFACTURING AND SUPPLY OF INSTRUMENTATION
12.2. Settings
12.2.1
Open.the.cover..Turn.on.the.device.by.pushing.POWER.“ ”.button.
12.2.2.After.switching.on.of.the.device.“on.default”.the.indicator.POWER.SUPPLY.VOLTAGE.
“
”.glows.green..The.device.is.in.the.“stop”.mode..The.pre-set.of.the.modes.and.parameters.
values.should.be.done.
12.2.3.If.it.is.necessary.to.change.the.indicated.mode.or.parameter,.it.can.be.done.by.sequenced.
presses.of.the.CHOICE.“
”..button.
In.this.case.(“along.the.loop”.and.“counterclockwise”).in.the.“Internal.parameters.field”.and.
“Modes. field”. one. can. choose. reference. and. variable. values. of. the. modes. and. parameters.
indicated.in.the.“Digital.field”..The.chosen.mode.and.parameter.marked.by.the.flash.of.the.relevant.
indicator.
The.sequence.of.the.indications.in.the.functional.fields.
1)
.“
”.-.POWER.SUPPLY.VOLTAGE.in.volts.(reference.value,.
green
.glow);
2)
.“ ”.-.active.“ANTENNA”.mode.and.the.type.of.connected.transmitted.antenna.(depends.on.
which.accessory.is.connected.to.the.“OUTPUT”.connector:
3)
.“
”.-.active./.non-active.“MODULATION”.and.the.type.of.the.special.signal.form.(should.
be.chosen.in.the.“Digital.field”.by.MORE/.LESS.“
”.buttons):
-.lack.of.glow.–.no.modulation.(continuous.signal.“
Co
”.“of.standard”.sin.form).
-.
green
.glow.–.pulse.modulation.mode.“
Pu
”.
-.
yellow
.glow.–.dual-frequency.modulation.mode.“
2F
”.
4)
“
f,kHz
”.-.frequency.of.the.generated.signal.in.kilohertz.(
green
.glow).is.chosen.in.the.“Digital.
field.by.LESS/.MORE.“
”.buttons:
-.for.loads.“clips”or.“clamp”.-.512Hz.“0.5”./.1024Hz.“1.0”./.8192Hz.“8.2”./.32768Hz.“33”.
-.for.“antenna”.modes.“In”.or.“An”.-.8192Hz.“8.2”./.32768Hz.“33”.
The..generation..frequency..is..set..if..possible..lower..but..according..to..recommendations..of..the..
chosen.utility.location.method.and..proceed..from..the..premise..that..the..lower..the..frequency:
-.the.less.re-inducing.to.the.nearby.facilities,.the.less.the.leakage.of.the.“revocable”.current,.the..
more.transmission.distance.
-..the..lower..sensitivity..of..the.utility..locators..(more..revocable..current..required..and..consequently.
power.of.transmitter)..The.more.difficult.to.overcome.the.communication.conductivity.flaws..
12.3 Clips(standard accessory for the “contact” connection)
12.3.1.If.clips/earrings.are.connected.to.the.“OUTPUT”,.the.device.is.ready.for.“contact”.load..
connection..The.internal.transmitting.inductor.“In”.is.not.connected.(“ANTENNA”.mode.indicator.
“
”.does.not.glow).
12.3.2..To..connect,.put.one..clip..to..the..input..of..the..examined.utility..and..the..second..
one. . to. . the. . earthing. . rod. . (or. . relevant. . earthing)..
at..maximum..distance.from.the.utility..The.opposite.
end.of.the.examined.utility.should.be.earthed.
12.3.3.By.pressing.the.button.START/STOP..“
”.
is. initiated. the. automatic. adjustment. process. with.
the.l..“occasional”.resistance.load..Along.with.this,.
the..output..signal..voltage..incrementally..increases..
up. . to. the. moment. when. the. specific. load. current.
value.is.reached.(or.exceeded).(0.2A.at.frequencies.
512Hz. “0. 5”/. 1024Hz. “1. 0”. /. “2F”. or. 0. 1A. at.
frequencies.8192Hz.“8.2”./.32768Hz.“33”)..If.the.load..resistance.is.too.high.for.reaching.these.
values.of.the.output.current,.then.the.maximum.possible..output.signal.voltage.is.produced..
12.3.4. . After. that,. manual. alterations. (by. LESS/MORE. “ . ”. . buttons). of. the. output. signal.
voltage.are.possible.in.the.range.of.provided.by.the.automation.