EN16
HI (over 5000 PPM)
PM 2.5
: 0 / HI (over 999 ug/m
3
)
TVOC
: 0.2 (below 0.2 mg/m
3
)/
HI (over 10 mg/m
3
)
Temperature
: LO (below 0°C / 32°F) /
HI (above 50°C / 122°F)
RH%
: 20% (below 20%) / 95% (over 95%)
Power Supply
: 5V DC, 1.2A adaptor
KA06E-0501200EU
Default Settings
CO
2
alert
: Low - 400, High
– 2000
PM 2.5 alert
: Low
– 0, High – 250
TVOC alert
: Low
– 0.2, High - 7
RH% alert
: Low
– 35%, High – 70%
Voice alarm
: Off
Temperature
: °C
Max-Min-Average value
Memory duration
: 12 HRS
Precautions
The item is intended to be used only indoors.
Do not subject the item to excessive force or shock.
Do not expose the item to extreme temperatures, direct
sunlight, dust or humidity.
Do not immerse in water.
Avoid contact with any corrosive materials.
Do not dispose this item in a fire as it may explode.
Do not open the inner back case or tamper with any
components of this item.
Use the product only for its intended purpose!