F3S-TGR-SBx-KxC series User’s 

manual 

 

 11

 

 
If several SLCs are used, care must be taken that each 

SLC

 does not 

interfere with the ones nearby; please install as follows: 
 
     Mirror1                      SLC1         SLC2                          Mirror2 

 

 
 
 
 
 
 
 
 
 
 
 
 

Install the SLC so that they emit in the opposite directions (Staggered) 

 
                       SLC1               Mirror2                             SLC1               Mirror1 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

          Mirror2               SLC2 

 
 
 
 
                      Mirror1                SLC2 
 
 
 
 

All these installation will prevent mutual interference between SLC. 

F3S-TGR-SBx-KxC series User’s 

manual 

 

 12

 

 
Insert a non-transparent wall if it is not possible to connect the SLC as 
shown previously. 
 
 
SLC1                   Mirror1      wall    SLC2                   Mirror2 
 
 
 
 
 
 
 
 
 
 
 
   

         SLC1   

     wall   

  SLC2 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
   

       Mirror1   

 

 

Mirror2 

 
The two bars 

must

 be mounted symmetrically as shown in the picture: 

 
 
 
 
 
 
 
 

   Top 

view 

Summary of Contents for F3S-TGR-SB-K2C-500 Series

Page 1: ...o it whenever necessary Do not open the housing or make any unauthorised modifications The power supply must be disconnected before proceeding with any external intervention Regulations and Standards...

Page 2: ...with any standards codes or regulations that apply to the combination of products in the customer s application or use of the product At the customer s request TECHNO GR will provide applicable third...

Page 3: ...2 2 2006 F3S TGR SBx KxC series User s manual 6 INDEX section page 1 OPERATION 7 2 PRECAUTIONS AND CRITERIA FOR INSTALLATION 8 2 1 CALCULATION OF THE MINIMUM DISTANCE FOR INSTALLATION 8 2 2 REFLECTING...

Page 4: ...ator must be connected when the SLC is not connected to the power supply as shown in section 6 and then the SLC s power supply must be restored To disable the muting function the LMS muting indicator...

Page 5: ...nearby surfaces Serious injuries can result if these effects are not taken into consideration Should there be any reflecting surfaces the distance must be sufficient to safeguard against passive refl...

Page 6: ...n the opposite directions Staggered SLC1 Mirror2 SLC1 Mirror1 Mirror2 SLC2 Mirror1 SLC2 All these installation will prevent mutual interference between SLC F3S TGR SBx KxC series User s manual 12 Inse...

Page 7: ...ves so the brackets d can be placed at an equal distance from each other Fixing facilities list 1 Movable nuts 8pcs 2 Fixing brackets 4pcs 3 Washer 8pcs 4 Grower 8pcs 5 Nut 8pcs F3S TGR SBx KxC series...

Page 8: ...ety relay module Muting input A and Muting input B can be provided by mechanical switch photoelectric sensors proximities switch with closed contact in the presence of the object to be detected The te...

Page 9: ...override the system and they should therefore be used with due care 7 2 MUTING FUNCTION As mentioned in the introduction the muting function can be enabled with any SLC by simply connecting the LMS m...

Page 10: ...ng 1 Wiring must be done correctly 2 The muting sensors must recognise the whole length of the material i e pallets vehicles 3 The sensors must be arranged so that the material is also recognised if i...

Page 11: ...Yellow 4 Muting input A Green 3 Input of A1 sensor Input of A2 sensor Input of B1 sensor Input of B2 sensor 24Vdc D a n g e r o u s z o n e F3S TGR SBx KxC series User s manual 22 Application with fo...

Page 12: ...imum dimension of package that can cross the SLC D1 distance between muting actuator B and SLC It MUST be as short as possible Minimum distance allowable depends on the speed of conveyour the response...

Page 13: ...time as long as the muting signals are valid Timing chart F ree Interrupted O N O F F O N O F F O N O F F A ctive O F F S LC O S S D M uting Input A M uting Input B M uting S tatus 0 03 sec Tm 3sec A...

Page 14: ...5 seconds The override function is now enabled The LMS muting indicator flashes to signal the exclusion of the SLC The maximum duration of the override function is 120 seconds after which the SLC is r...

Page 15: ...1 and 4 2 Check that it is not possible for a person to get between the SLC and the dangerous parts of the machinery Check that there is no external damage to the SLC and or to the external electrical...

Page 16: ...SBx K3C 800 941 mm F3S TGR SBx K4C 900 1041 mm F3S TGR SBx KxC series User s manual 32 ITEM SPECIFICATION Materials Housing Front panel Sealing gasket Connector parts Powder coated aluminum Polycarbo...

Page 17: ...Reverse polarity Overload Short circuit pulsed Input circuit Logical Zero level 0 8V Logical One level 14 24Vdc Input pulse duration Min 2 cycle time Response time 16ms Reset time TOFF TON interlock 3...

Page 18: ...xC series User s manual 35 MODEL A B C D E L F3S TGR SBx K2C 500 500 514 614 F3S TGR SBx K3C 800 118 400 60 340 814 958 F3S TGR SBx K4C 900 118 300 300 300 914 1058 F3S TGR SBx KxC series User s manua...

Reviews: