ITEM
SPECIFICATION
Output circuit protection
PNP short circuit protected
Output current
250 mA each OSSD
Max. Capacitive load
200nF (pure capacitive load)
Output voltage drop
< 2.0 V
(excl. voltage drop due to cable
extension)
Residual current
< 100 µA
Circuit protection
Reverse polarity,
Overload
Short-circuit (pulsed)
Input circuit
Logical Zero level 0 – 8V
Logical One level 14 – 24Vdc
Input pulse duration
Min. 2 cycle time
Response time
≤
16ms
Reset time (T
OFF
Æ
T
ON
) (interlock)
≤
300ms
Insulation resistance
800 M
Ω
@ 500Vdc
Dielectric voltage strength
350Vac, 50/60 Hz (1 min)
Configuration
Manual reset / Automatic reset
(default)
Operating modes
Muting / Override (by wiring setting)
F3S-TGR-SBx-KxC series User’s
manual
34
13 DIMENSIONS
All dimensions are shown in millimetres
Mounting bracket