Page 34 • MN06150 ║ Issue/Rev. 0.7 (9/18)
Section IV – Diagrams
MNET Board
CN1
CN2
1 Tx-
2 Tx+
3 Rx+
4 Rx-
5
6
7
8
9
10
1
2
3
4
5
Promass
26
TX + / RX +
27
TX - / RX -
Figure 21. Promass Coriolis Meter Communications (RS485)
Programming
Parameter
microLoad
Promass
Baud Rate
38400
38400
Parity
8/No Parity/2 Stop bits
No Parity, 2 Stop bits
Modbus Endian
Big
Byte order 3-2-1-0
Sequence Number
1
Address 1
Mass Meter Type
E+H Promass
Timeout
0
Transmission Mode
RTU
Reply delay
10mS
Mode
Note:
Wiring example is shown on comm 2: comm 3 can be used as well.