![TechnipFMC Smith Meter C2 Service Manual Download Page 13](http://html1.mh-extra.com/html/technipfmc/smith-meter-c2/smith-meter-c2_service-manual_1069432013.webp)
Issue/Rev. 0.6 (12/18) ║ MN01005 • Page 13
During disassembly of the inner mechanism, clearance may be checked (see Clearance Check
section) to determine the condition for various parts. To be done accurately, a spider should be
used. This fixture maintains inner housing concentricity when the cover is removed. Contact your
TechnipFMC authorized distributor for availability.
Take out the machine screw and plate (on JA10 meters, shaft nut) located on underside of housing.
Remove the rotor from the housing, Figure 18. Lift out carefully to prevent damaging blades.
2-Bladed Double Case PD Meters Service Manual
Disassembly
Figure 17
Figure 18