![Technify Motors Cessna 172 Maintenance Manual Download Page 24](http://html.mh-extra.com/html/technify-motors/cessna-172/cessna-172_maintenance-manual_1069072024.webp)
Supplement Airplane Maintenance Manual
Cessna 172 with TAE 125-02-99 / -114
AMM-20-02
Chapter:
Issue:
Issue Date:
Page:
Content:
20-AMM-05-02
3
06.11.2013
6
8
Rev. No:
Rev. Date:
1
25.08.2014
Every 25 years
•
Renew following electrical components (refer to Chapter
24, Section 24.30, Maintenance Practices and airplane
manufacturer´s specifications):
- Main battery according to Gill Battery Service
- Battery relay
- ALT / Battery switch
- Alternator relay
- Battery fuse
- Alternator fuse, if installed
- 50A FADEC fuse
- 100A Main Bus fuse
- FADEC IGN switch
C. Airframe Group
5.20.03
Checks dependent on engine operating time:
Every 100 operating hours/annual inspection
•
Inspect cowling openings (oil inspection cover, air ducts) for
damage
•
Inspect all supports for main battery, FADEC Backup
battery, excitation batteries etc.
•
Check Load Selector mechanism
•
Check fuel selector mechanism
•
Inspect the fuel system for cracks, distortion, corrosion and
loose fittings
•
Inspect the exhaust system
•
Check alternate air door function
•
Check heater control mechanism
Summary of Contents for Cessna 172