![Technifor TD412 Operating And Maintenance Manual Integration Download Page 55](http://html1.mh-extra.com/html/technifor/td412/td412_operating-and-maintenance-manual-integration_1069070055.webp)
A
Incidents and resolution of the problems
H
Ref. DCD01/3078 - TD412_en_C
55/62
Summary table of the error codes
Possible error
codes
Description
E1
E2
SHUTTER DEFECT
E3
T° HIGH CRYSTAL
E4
T° HIGH BOARD
E5
T° LOW DIODE
E6
T° HIGH DIODE
E7
E8
POWER SUPPLY ERROR
E9
OVERVOLTAGE DIODE
E10
CURRENT ERROR
E11
OVERCURRENT DIODE
E12
T° DIODE ERROR
E13
CURRENT REGULATION
E14
INTERLOCK
E15
PELTIER ERROR
E16
E17
T° SENSOR FAN ERROR
E18
T° LOW CRYSTAL
E19
T° LOW BOARD
E20