2. Marking area
Diagram showing marking areas for the 4 available lenses (F 100, F 160, F 254, F 330)
1 : Marking area (mm)
2 : Focal lens
3. Height adjustment
For optimal marking quality, the part must be placed at the proper distance from the marking head. This is the
focal distance or working distance.
This distance varies depending on the focal lens used and the specific characteristics of the machine’s laser
beam (diameter and beam divergence).
These values are approximative.
Distances may vary approxi/- 15 mm (0.591 in) depending on the laser’s and focal lens’ specific
characteristics.
1
2
LENS
X (mm)
Y (mm)
f 100
86
92
f 160
162
168
f 254
306
312
f 330
421
427