![Technics SX-KN6500 Service Manual Download Page 6](http://html1.mh-extra.com/html/technics/sx-kn6500/sx-kn6500_service-manual_1068509006.webp)
2. Safety Precaution
2.1. Safety Precaution
1. Before servicing, unplug the power cord to prevent an electric
shock.
2. When replacing parts, use only the manufacturer’s recommended
components for safety.
3. Check the condition of the power cord. Replace if wear or damage
is evident.
4. After servicing, be sure to restore the lead dress, insulation
barriers, insulation papers, shields, etc.
5. Before returning the serviced equipment to the customer, be sure
to make the following insulation resistance test to prevent the
customer from being exposed to a shock hazard.
2.2. Insulation Resistance Test
1. Unplug the power cord and short the prongs of the plug with a
jumper wire.
2. Turn on the power switch.
3. Measure the resistance value with an ohmmeter between the
jumpered AC plug and each exposed metal cabinet part, such as
screw heads, connectors, control shafts, handle brackets, etc.
Measurements should range from 4 MOhm to infinity for
allexposed parts. (refer to
Fig.1
)
Fig.1
6
Summary of Contents for SX-KN6500
Page 8: ...10 Parts Location 8...
Page 30: ...30...
Page 37: ...C26 ECUV1H104ZFX 50V 0 1 1 MAIN SPC 37...
Page 49: ...L1 QLBG003A COIL 1 MAIN SPC 49...
Page 51: ...PCB18 SXPG232941 ACP P C B 1 EG EZ EB RTL M 51...
Page 55: ...R19 ERDS2TJ103 1 4W 10K 1 CPL SPC 55...
Page 63: ...X301 QSIG1I3000A 30MHZ CERAMIC OSCILLATOR 1 MAIN M 63...
Page 66: ...22 Manual Keyboard Parts and Control Panel Parts Location 66...
Page 67: ...67...