Technibel K 60 D 070 Z Installation Instructions Manual Download Page 2

GB

2

CONTeNTs

1 - Purpose - Use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2 - Precautions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3 - Composition  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
4 - Operating principle  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
5 - Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
6 - Connections on the heat pump . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
7 - Starting - Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

1 - PURPOse - Use

• Control kit designed to control heating installations with heat pump and electric support heater for residential purposes within

the scope of applications meant for TECHNIBEL. See technical control file enclosed with kit.

MARKING 

This product, marked with the

symbol, complies with the essential requirements of the following Directives:

- Low voltage No. 2006/95/EC.
- Electromagnetic Compatibility No. 2004/108/EC.

NOTe

: This symbol mark and recycle system are applied only to EU countries and not applied to the countries in the other

area of the world.

Your product is designed and manufactured with high quality materials and components which can be recycled and reused.
At end of livetime, it should be eliminated separately from your household waste.
Please dispose of this equipment at your local community waste collection / recycling centre.
In the European Union there are separate collection systems for used electrical and electronic products.
Please help us to conserve the environment we live in!

2 - PReCAUTIONs

Installation, commissioning and maintenance of this kit must be performed by qualified and authorised personnel, in

accordance with current standards and recognized trade practices.

Before doing any work on the installation, make sure it is switched off and all power supplies locked out.

IMPORTANT

• Consult the manuals of the system's various components:

- heat pump,
- control kit,
- 2 zones module, if any,
- DHW preparation tank, if any,

as well as the technical control file supplied with the kit.

Before each start-up operation, make sure that the it is properly configured for the application.

CAUTION

Summary of Contents for K 60 D 070 Z

Page 1: ...iNveRteR avec chaUFFaGe d appoiNt LectRiqUe system coNtRoL kit FoR iNveRteR heat pUmp with eLectRic sUppoRt heateR Mai 2013 10 11 566 F GB 02 k 60 d 070 z F GB Notice d iNstaLLatioN iNstaLLatioN iNstR...

Page 2: ...rials and components which can be recycled and reused At end of livetime it should be eliminated separately from your household waste Please dispose of this equipment at your local community waste col...

Page 3: ...Priority is given to thermodynamic heating See operating details in the technical control file supplied with this kit The system control kit K60D070Z is appropriate for standard applications using he...

Page 4: ...ves or behind curtains near sources or heat or directly exposed to sunlight The unit should be installed approximately 1 5 m above the floor Open the unit by removing the lower screw and secure the ba...

Page 5: ...min size 0 5 mm2 Maximum length 25 meters To be connected to the s13 1 and s13 2 terminals if terminal strip Note This sensor must be located outside in a location that is representative of the temper...

Page 6: ...1 Note The electrical power supplied to the convectors must be the same as that of the heat pump 6 2 heAT PUMP CONNeCTION DIAGRAM Route the pilot wire 230 V separately from the other control connectio...

Page 7: ...routed near 230 VAC cables Particular attention should be paid to the 230 VAC pilot wire Electrical connection conduits must be fixed ROUTING Of heAT PUMP CABles Route the cables through the cable gla...

Page 8: ...Due to our policy of continuous development our products are liable to modification without notice Z I Route d partementale 28 CS 40131 Reyrieux 01601 TR voux Cedex FRanCe T l 04 74 00 92 92 Fax 04 74...