TAPPING
6
SCREW
11/98
10 11 305 F.GB.I.E.D.01
DECLARATION OF CONFORMITY
This product is marked as it satisfies Directives:
– Low voltage no. 73/23 EEC and 93/68 EEC.
– Electromagnetic compatibility no. 89/336 ECC, 92/31 EEC
and 93/68 EEC.
This declaration will become void in case of of misuse and/or
non observance though partial of manufacturer's installation
and/or operating instructions.
COOLING ONLY MODELS
OPERATING LIMITS
L
Maximum conditions
Outdoor temperature :
52°C D.B.*
Room temperature
:
35°C D.B. / 22.5°C W.B.
L
Minimum conditions
Outdoor temperature :
19°C D.B.**
Room temperature
:
19°C D.B. / 14°C W.B.
L
Model name GRXXXL
*
* : 50°C D.B.
** : –15°C D.B.
COOLING ONLY MODELS (R407C)
OPERATING LIMITS
L
Maximum conditions
Outdoor temperature :
43°C D.B.*
Room temperature
:
32°C D.B. / 23°C W.B.
L
Minimum conditions
Outdoor temperature :
19°C D.B.**
Room temperature
:
19°C D.B. / 14°C W.B.
L
Model name GRVXXXL
*
* : 43°C D.B.
** : –15°C D.B.
HEAT PUMP MODELS
OPERATING LIMITS
L
Cooling Maximum conditions
Outdoor temperature :
46°C D.B.
Room temperature
:
35°C D.B. / 22°C W.B.
L
Cooling Minimum conditions
Outdoor temperature :
19°C D.B.
Room temperature
:
19°C D.B. / 14°C W.B.
L
Heating Maximum conditions
Outdoor temperature :
24°C D.B. / 18°C W.B.
Room temperature
:
27°C D.B.
L
Heating Minimum conditions
Outdoor temperature :
–8°C D.B. / –9°C W.B.
ACCESSORIES SUPPLIED WITH THE UNIT
PARTS
FIGURE
Q.TY
PARTS
FIGURE
Q.TY
RAWL PLUG
7
PLASTIC
1
COVER
HEX
1
WRENCH
REMOTE
1
CONTROL UNIT
REMOTE CONTROL
1
UNIT SCREW
AAA ALKALINE
2
BATTERY
DRAIN
1
ELBOW
*
*
Available only for heat pump models.
EG
INSTALLATION INSTRUCTIONS
- Split system air conditioner -
Power Supply:
The last digit(s) of the model number indicates the required
power supply to the unit.
5: 220 - 240 V ~ 50 Hz / 7: 380-400 V - 3N ~ 50 Hz
Last digit(s) of the model number
1. Standard screwdriver
2. Phillips head screwdriver
3. Knife or wire stripper
4. Tape measure
5. Level
6. Sabre saw or key hole saw
7. Hacksaw
8. Core bits ø 5
1
9. Hammer
10. Drill
11. Tube cutter
12. Tube flaring tool
13. Torque wrench
14. Adjustable wrench
15. Reamer (for reburring)
Model Combinations
Combine indoor and outdoor units only as listed below.
COOLING ONLY MODELS R22
Indoor Units
Outdoor Units
MAV184C5
GR185C5
GR185L5
GR185C7
GR185L7
MAV224C5
GR226C5
GR226C7
HEAT PUMP MODELS R22
Indoor Units
Outdoor Units
MAV185R5
GR184R5
MAV225R5
GR224R5
COOLING ONLY MODELS R407C
Indoor Units
Outdoor Units
MAV184C5
GRV185C5
GRV185L5
GRV185C7
GRV185L7
MAV224C5
GRV226C5
GRV226C7
HEAT PUMP MODELS R407C
Indoor Units
Outdoor Units
MAV185R5
GRV184R5
MAV225R5
GRV224R5
R407C MODELS: for the other installation works of MAVx models
refer to the “Installation Instructions” (green pages) on the top of the
outdoor unit.
Tools required for installation (not supplied)