background image

9

EG

FILTER CLEANING

Use a vacuum cleaner to remove light dust. If there is 

sticky dust on the filter, wash the filter in lukewarm, 

soapy water, rinse it in clean water, and dry it.

AIR FILTER

l

 Never use solvents, or harsh chemicals when cleaning 

the indoor unit. Do not wipe the plastic casing using very 

hot water.

l

 Some metal edges and the vanes are sharp and may 

cause injury if handled improperly; be especially careful 

when you clean these parts.

l

 The internal coil and other components of the outdoor 

unit must be cleaned every year. Consult your dealer or 

service centre.

CAUTIoN

2.  WhEN ThE AIR CoNDITIoNER IS RUNNING

If you want to turn off the air conditioner push the 

OPERATION selector with a pen until the OPERATION 

lamp is turned off.

Power failure during operation.

In the event of power failure, the unit will stop. When the 

power is resumed, the unit will restart automatically after 

3 minutes.

NoTE

If you have lost the remote control unit or it has troubles, 

follow the steps below.

1. 

WHEN THE AIR CONDITIONER IS STOPPED

If you want to turn on the air conditioner push the 

OPERATION selector with a pen to select the desired 

mode (COOL or HEAT).

OPERATION WITHOUT THE REMOTE

CoNTRoL UNIT

The air conditioner will start in hIGh fan speed. 

The temperature setting is 25°C for cooling mode and 

21°C for heating mode.

NoTE

CARE AND CLEANING

l

 

Maintenance operations must be carried out by specially 

trained personnel.

l

 

For safety, be sure to turn the air conditioner off and also 

to disconnect the power before cleaning.

l

 

Do not pour water on the indoor unit to clean it. This will 

damage the internal components and cause an electric 

shock hazard.

WARNING

CASING AND GRILLE (INDooR UNIT)

Clean the casing and grille of the indoor unit with a vacuum 

cleaner brush, or wipe them with a clean, soft cloth.

If these parts are stained, use a clean cloth moistened with 

a mild liquid detergent.

When cleaning the grille, be careful not to force the vanes 

out of place.

OPERATION

selector

The air filter should be cleaned at least once every 

six months or more frequently; it depends on the real 

operation conditions.

1.

2.

Summary of Contents for DSA10FICR5IBA

Page 1: ...A NOTICE D UTILISATION OPERATING INSTRUCTIONS ISTRUZIONI D USO INSTRUCCIONES DE USO BEDIENUNGSANLEITUNG Split air conditioner system Condizionatore d aria split system Climatiseurs split Split klimage...

Page 2: ...UBLESHOOTING 10 EXPLANATION AND USE OF THE REMOTE CONTROL UNIT S MICROSWITCHES 14 NOTE PRODUCT INFORMATION If you have problems or questions concerning your Air Conditioner you will need the following...

Page 3: ...WARNING EG NAME OF PARTS AND OPERATION SELECTOR switch 5 6 7 8 9 3 10 11 2 1 4 NOTA When the unit receives a signal from the remote controller all the three lamps OPERATION TIMER and STANDBY light up...

Page 4: ...he remote control unit and check the settings of the four microswitches as shown below TEMPERATURE SENSOR SELECTOR l Under normal conditions the room temperature is detected and checked by the tempera...

Page 5: ...THE TIMER IFEEL IFEEL C SENSOR SELECTOR Press this button to modify the active setting for room temperature detection from remote controller to air conditioner and viceversa FAN BUTTON fan speed Fan...

Page 6: ...SHOW THE ROOM TEMPERATURE AGAIN 3 Press the FAN selector button to the setting you want During Automatic Operation IFEEL ON the set temperature is understood as perceived one then the system is automa...

Page 7: ...es the operation mode cooling or heating for all the other units that will be switched on after the first one when the system has been switched on in cooling mode and one unit is activated in heating...

Page 8: ...utton to turn the air conditioner off l Wait for the indoor unit to stop operating l Press the ON OFF button again to turn the air conditioner on SETTING THE 1 HOUR TIMER This function causes the unit...

Page 9: ...has troubles follow the steps below 1 When the air conditioner is stopped If you want to turn on the air conditioner push the OPERATION selector with a pen to select the desired mode COOL or HEAT OPE...

Page 10: ...ble the air conditioner does not run at all Possible cause 1 Power failure 2 Leakage breaker tripped 3 Operation button is OFF 4 Batteries in remote control unit have run down Remedy 1 Restore power 2...

Page 11: ...and flap is closed The system restarts automatically as soon as the problem on the out door unit is solved Check the error code using the appro priate LEDs on the PCB of the outdoor unit Follow the in...

Page 12: ...ck that the dip switch SW2 for communication address setting is in the correct position Check that all earth cables are properly connected to every terminal C h e c k t h a t t h e s h i e l d o f t h...

Page 13: ...cal wiring diagram Check that the sensor is not damaged and if necessary replace it E6 O F F Fan motor error Fan is stopped and flap is closed The system restarts automatically after some seconds Chec...

Page 14: ...providing this service Disposing of a battery separately avoids possible negative effects on the environment and human health deriving from an inappropriate disposal and enables its components to be...

Page 15: ...Z I Route d partementale 28 01600 Reyrieux France T l 33 4 74 00 92 92 Fax 33 4 74 00 42 00 Technibel is a trademark of NIBE ENERGY SYSTEM FRANCE...