6

EG

AUTOMATIC OPERATION

DEFRoSTING oF oUTDooR UNIT hEAT 

EXCHANGER

When the outdoor temperature is low, frost or ice may 

appear on the heat exchanger coil, reducing the heating 

performance. When this happens, a protection function 

for the heat exchanger defrosting is activated. During this 

function operation, the fan of the indoor unit stops. Heating 

operation restarts after several minutes. (This interval 

will vary slightly depending on the room and outdoor 

temperature).

HEATING PERFORMANCE

A heat pump conditioner heats a room by taking heat 

from outside air. The heating efficiency will fall off when 

the outdoor temperature is very low. If enough heat is not 

obtained with this air conditioner, use another heating 

appliance in conjunction with it.

ON

ON

ON

∆    1    H

∆    1    H

MIN.

MAX.

A

B

C
C

B

A

27
26
25
24
23
22
21
20
19

Example of operation diagram in the          (Auto) mode 

with the set room temperature at 

23°C

.

NoTE

The air conditioner changes the operation mode (from cool 

to heat or vice versa, if one of the following conditions 

occurs:

ZoNE A:

 changes if the difference between the room 

temperature and the temperature set on the remote 

control unit is at least 3°C..

ZoNE B: 

changes if the difference between the room 

temperature and the temperature set on the remote 

control unit is at least 1°C, one hour after the compressor 

stop.

ZoNE C:

 never changes if the difference between the 

room temperature and the temperature set on the remote 

control unit is no more than 1°C.

1. 

Set the          or          selector to AUTO (symbol          on the 

display; also the symbol        or         remains displayed).

2. 

Press the +/- buttons (temperature selection) to set the 

desired temperature (the temperature range is between 

32 °C max. and 10 °C min.).

When this setting is selected, the air conditioner will operate 

automatically switching to the COOL or HEAT mode as 

appropriate (regardless of the symbol displayed).

THE DISPLAY SHOWS THE 

SELECTED TEMPERATURE.

AFTER 5 SECONDS FROM THE 

REQUIRED TEMPERATURE SETTING 

THE DISPLAY WILL SHOW THE ROOM 

TEMPERATURE AGAIN.

3. 

Press the FAN selector button to the setting you want.

During Automatic Operation (+ IFEEL ON) the set 

temperature is understood as perceived one, then the 

system is automatically adjusted not only according to the 

air temperature, but also based on the relative humidity, 

according to the “humidex” index. 

Verify that the unit is connected to the 
main power and the STANDBY lamp is 
light up.

1. 

Set  the          selector to COOL (symbol 

on the display).

2. 

Press the +/- buttons (temperature 

selection) to set the desired temperature 
(the temperature range is between 32 °C 
max. and 10 °C min.).

HOW TO SET THE PRESENT TIME

hEATING 

1. 

Press the button ST three times.

 

The time indication alone flashes.

2. 

Press the H button until the present time hour is 

displayed. Press the M button until the present time 

minutes are displayed. The display will automatically 

stop flashing.

1. 

Set the          selector to HEAT (fixed or blinking symbol       

on the display.

2. 

Press the +/- buttons (temperature selection) to set 

the desired temperature (the temperature range is between 
32 °C max. and 10 °C min.).

THE DISPLAY SHOWS THE 

SELECTED TEMPERATURE.

AFTER 5 SECONDS FROM THE 

REQUIRED TEMPERATURE SETTING 

THE DISPLAY WILL SHOW THE ROOM 

TEMPERATURE AGAIN.

3. 

Press the FAN button to select the fan speed.

For several minutes after the start of heating operation, the 

indoor fan will stop until the indoor heat exchanger coil has 

warmed up sufficiently. This is because the COLD DRAFT 

PREVENTION SYSTEM is operating. During this period, 

the STANDBY lamp remains lit.

NoTES

CooLING

THE DISPLAY SHOWS THE 

SELECTED TEMPERATURE.

AFTER 5 SECONDS FROM THE 

REQUIRED TEMPERATURE SETTING 

THE DISPLAY WILL SHOW THE ROOM 

TEMPERATURE AGAIN.

3. 

Press the FAN button to select the fan speed.

NoTE

C

1

 3

2

2

1

Generally the fan stops when the set temperature is 
exceeded (when you have selected the fixed  HEATING 
symbol         ).

hEATING RECIRCULATIoN FUNCTIoN

If you want to let the fan run even after the set temperature is 
exceeded, for example, in order to make the heating, coming 
from a nearby source, circulate (eg. fireplace installed under 
the air conditioner), press the selector          until the blinking 
HEATING symbol         is displayed.

Summary of Contents for DSA10FICR5IBA

Page 1: ...A NOTICE D UTILISATION OPERATING INSTRUCTIONS ISTRUZIONI D USO INSTRUCCIONES DE USO BEDIENUNGSANLEITUNG Split air conditioner system Condizionatore d aria split system Climatiseurs split Split klimage...

Page 2: ...UBLESHOOTING 10 EXPLANATION AND USE OF THE REMOTE CONTROL UNIT S MICROSWITCHES 14 NOTE PRODUCT INFORMATION If you have problems or questions concerning your Air Conditioner you will need the following...

Page 3: ...WARNING EG NAME OF PARTS AND OPERATION SELECTOR switch 5 6 7 8 9 3 10 11 2 1 4 NOTA When the unit receives a signal from the remote controller all the three lamps OPERATION TIMER and STANDBY light up...

Page 4: ...he remote control unit and check the settings of the four microswitches as shown below TEMPERATURE SENSOR SELECTOR l Under normal conditions the room temperature is detected and checked by the tempera...

Page 5: ...THE TIMER IFEEL IFEEL C SENSOR SELECTOR Press this button to modify the active setting for room temperature detection from remote controller to air conditioner and viceversa FAN BUTTON fan speed Fan...

Page 6: ...SHOW THE ROOM TEMPERATURE AGAIN 3 Press the FAN selector button to the setting you want During Automatic Operation IFEEL ON the set temperature is understood as perceived one then the system is automa...

Page 7: ...es the operation mode cooling or heating for all the other units that will be switched on after the first one when the system has been switched on in cooling mode and one unit is activated in heating...

Page 8: ...utton to turn the air conditioner off l Wait for the indoor unit to stop operating l Press the ON OFF button again to turn the air conditioner on SETTING THE 1 HOUR TIMER This function causes the unit...

Page 9: ...has troubles follow the steps below 1 When the air conditioner is stopped If you want to turn on the air conditioner push the OPERATION selector with a pen to select the desired mode COOL or HEAT OPE...

Page 10: ...ble the air conditioner does not run at all Possible cause 1 Power failure 2 Leakage breaker tripped 3 Operation button is OFF 4 Batteries in remote control unit have run down Remedy 1 Restore power 2...

Page 11: ...and flap is closed The system restarts automatically as soon as the problem on the out door unit is solved Check the error code using the appro priate LEDs on the PCB of the outdoor unit Follow the in...

Page 12: ...ck that the dip switch SW2 for communication address setting is in the correct position Check that all earth cables are properly connected to every terminal C h e c k t h a t t h e s h i e l d o f t h...

Page 13: ...cal wiring diagram Check that the sensor is not damaged and if necessary replace it E6 O F F Fan motor error Fan is stopped and flap is closed The system restarts automatically after some seconds Chec...

Page 14: ...providing this service Disposing of a battery separately avoids possible negative effects on the environment and human health deriving from an inappropriate disposal and enables its components to be...

Page 15: ...Z I Route d partementale 28 01600 Reyrieux France T l 33 4 74 00 92 92 Fax 33 4 74 00 42 00 Technibel is a trademark of NIBE ENERGY SYSTEM FRANCE...

Reviews: