CONTACTS FOR BUILDING AUTOMATION
INPUT CONTACT (J4 - green) - AVAILABLE ONLY IF "BOILER CONNECTION KIT" IS NOT
INSTALLED
The status of this input affects system operation according to the following:
Contact OPEN : system does not operate (always OFF) – inputs from wireless remote controller are not
processed
Contact CLOSED: system operates in the normal way according to the inputs coming from wireless
remote controller
OUTPUT CONTACT (J12)
This connector is directly tied to the contact (normally open) of a power relay which activates every time
the following alarm condition occur:
•
RAT damaged
•
ICT damaged
In this case when alarm happens, on poles 1 and 3 of J12 connector, 220 VAC-50Hz are available.
Max electrical load:
1A- 240VAC
24