WHEN DIFFERENCE BETWEEN
ROOM TEMPERATURE AND SET
FAN SPEED
TEMPERATURE IS
Cooling and
2 °C and over
High
dehumidifying
Between 2 and 1 °C
Medium
modes:
Below 1 °C
Low
2 °C and over
High
Heating mode:
Below 2 °C
Medium
The above mentioned data make reference to the
conditioner operating when the sensor on the remote control
unit is ON. (Refer to temperature sensor selector). If the
sensor on the unit is being used then actual operation will
slightly differ from that described in the above tables.
ADJUSTING THE FAN SPEED
AUTOMATIC
Simply set the FAN SPEED selector to the position.
A microcomputer automatically controls the fan speed when
the AUTO mode is selected. When the air conditioner starts
operating, the difference between the room temperature
and the set temperature is detected by the microcomputer
which then automatically switches the fan speed to the
most suitable level.
High speed
Med. speed
Low speed
MANUAL
If you want to manually adjust speed just set the FAN SPEED
selector as desired.
NOTE
1°C
1°C
1 hour
1 hour
TIME
Setting temperature Room temperature
COOLING AND DEHUMIDIFYING
1
°
C
1
°
C
1 hour
1 hour TIME
Setting temperature
Room temperature
HEATING
SLEEP MODE
●
The SLEEP mode enables you to save energy.
1.
Set the MODE selector to cool, dry or heat.
2.
Press the SLEEP button.
3.
The mark appears on the display. Press the
SLEEP button again to release the SLEEP function.
What does the SLEEP mode mean?
In this mode, the air conditioner will cool or heat the room
to the set temperature, and then the thermostat will make
the unit pause. After about 1 hour, the air conditioner will
automatically reset the set temperature as follows (also
refer to graphs).
OPERATING MODE
SET TEMPERATURE CHANGE
Heating
Lowered by 1 °C
Cooling and Dehumidifying
Raised by 1 °C
When the room temperature reaches the new set value,
the thermostat will cause the unit to pause. After about 1
hour the temperature will be raised by 1 °C in cooling, or
lowered by 1 °C in heating. This enables you to save energy
without sacrificing your comfort.
1
2
EG
DEHUMIDIFYING (DRY)
1.
Set the MODE selector switch to “DRY”
.
2.
Press the ON/OFF button and switch the air conditioner
ON.
3.
Press the TEMP. buttons (
3
) to set the room temperature
(the temperature range is between 30 °C max. and 16 °C
min.).
At this point the unit executes cycles of turning ON/OFF
automatically.
NOTE: The set room temperature could decrease.
THE DISPLAY SHOWS THE
SELECTED TEMPERATURE.
NOTE
●
Use DRY operation when you want to reduce the humidity
in the room.
●
During DRY operation, the fan speed is automatically set
to low or stops to prevent overcooling.
NOTE
The air conditioner changes the operation mode (from cool
to heat or vice versa, if one of the following conditions
occurs:
-
ZONE A:
changes if the difference between the room
temperature and the temperature set on the remote control
unit is at least 3°C..
-
ZONE B:
changes if the difference between the room
temperature and the temperature set on the remote control
unit is at least 1°C, one hour after the compressor stop.
-
ZONE C:
never changes if the difference between the
room temperature and the temperature set on the remote
control unit is no more than 1°C.
FAN ONLY
If you want to make air circulate without any temperature
control, follow these steps:
1.
Set the MODE selector switch to “FAN”
.
2.
Press the ON/OFF button and switch the air conditioner
ON.
NOTE
In FAN Only mode the fan speed is adjusted automatically
as in cooling mode.