Outdoor Unit:

GRF129R5IAA

Compressor

Type
Compressor model
Nominal input

W

Compressor oil…Amount

cc.

Coil resistance (Ambient temp. 20°C)

Overload relay
Safety devices

Type
Operating Temp. Open

°C

Close

°C

Fan & Fan Motor

Type
Q'ty ……. Dia.
Fan motor model…Q'ty
No. Of poles…rpm
Nominal output

W

Coil resistance (Ambient temp. 25 °C )

Safety devices

Type
Operating temp. Open

°C

Close

°C

Heat Exch. Coil

Coil
Rows
Fin pitch

mm

Face area

m

2

External Finish

DATA SUBJECT TO CHANGE WITHOUT NOTICE

-
-
-

8 …  variable ( 200 ÷ 800 )

20

BRN-BLK: 210

BRN-YEL: 210

YEL-BLK: 210

Propeller

1…. Ø 370

P35810 PO011

Rotary (Hermetic) DC inverter

G4A110LUBJR

1018

-
-

FV50S         340

0,48

software protection

-

Acrylic baked-on enamel finish

Aluminium plate fin  / Copper tube

2

1,4

0,34

8

Summary of Contents for 387107099

Page 1: ...TECHNICAL DATA SERVICE MANUAL OUTDOOR UNIT GRF99R5IAA GRF129R5IAA SPLIT SYSTEM AIR CONDITIONER 0 8180 580 00 05 2009 GRF129R5IAA 387107099 Model No Product Code No GRF99R5IAA 387107101...

Page 2: ...t allow wiring to touch the refrigerant tubing compressor or any moving parts of the fan Do not use multi core cable when wiring the power supply and control lines Use separate cables for each type of...

Page 3: ...specifications 7 2 3 Other Component specifications 9 3 DIMENSIONAL DATA 10 4 REFRIGERANT FLOW DIAGRAM 11 5 PERFORMANCE DATA 13 5 1 Performance Charts 13 6 ELECTRICAL DATA 15 6 1 Electrical character...

Page 4: ...or Air Intake Temp Cooling Maximum 32 C D B 23 C W B 43 C D B Minimum 10 C D B 6 C W B 15 C D B GRF98R5IAA GRF128R5IAA Heating Maximum 27 C D B 24 C D B 18 C W B Minimum 5 C D B 15 C D B Temperature I...

Page 5: ...ide tube mm in Dimensions Weight Unit dimensions Height mm Width mm Depth mm Package dimensions Height mm Width mm Depth mm Weight Net kg Shipping kg Shipping volume m3 DATA SUBJECT TO CHANGE WITHOUT...

Page 6: ...nsions Weight Unit dimensions Height mm Width mm Depth mm Package dimensions Height mm Width mm Depth mm Weight Net kg Shipping kg Shipping volume m3 DATA SUBJECT TO CHANGE WITHOUT NOTICE Remarks Rati...

Page 7: ...Fan motor model Q ty No Of poles rpm Nominal output W Coil resistance Ambient temp 25 C Safety devices Type Operating temp Open C Close C Heat Exch Coil Coil Rows Fin pitch mm Face area m2 External F...

Page 8: ...es rpm Nominal output W Coil resistance Ambient temp 25 C Safety devices Type Operating temp Open C Close C Heat Exch Coil Coil Rows Fin pitch mm Face area m2 External Finish DATA SUBJECT TO CHANGE WI...

Page 9: ...ng Coil resistance at 20 C Thermistor Coil sensor Resistance k Thermistor compressor discharge sensor Resistance k Thermistor inlet air sensor Resistance k Crank case heater Resistance at 20 C Base he...

Page 10: ...IONAL DATA 700 540 15 470 4 12 holes 116 320 294 Air intake Air discharge 255 10 170 103 57 Narrow tube service valve 6 35 1 4 Wide tube service valve 9 52 3 8 12 7 1 2 7000 9000 BTU h 12000 BTU h Uni...

Page 11: ...4 REFRIGERANT FLOW DIAGRAM Indoor Unit MRAF99R5IAA Outdoor Unit GRF99R5IAA MRAF129R5IAA GRF129R5IAA 11...

Page 12: ...wet floors due to dripping of condensation both tubes must be well insulated with a proper insulation material The thickness of the insulation should be a min 8 mm After a tube has been insulated nev...

Page 13: ...34 0 0 5 10 15 20 Outdoor inlet air D B C High pressure at wide tube service valve MPa 4 0 4 5 5 0 5 5 6 0 6 5 7 0 10 15 20 25 30 35 40 Outdoor inlet air D B temp C Compressor phase current A Indoor...

Page 14: ...r inlet air D B C Low pressure at wide tube service valve MPa 32 0 32 5 33 0 33 5 34 0 34 5 0 5 10 15 20 Outdoor inlet air D B C High pressure at wide tube service valve Mpa 5 5 5 7 5 9 6 1 6 3 6 5 6...

Page 15: ...C D B HEATING Indoor Unit Complete Unit Fan Motor Fan Motor Compressor performance at Rating conditions Running Amps A 0 12 3 6 Power input Kw 0 027 0 790 Rating Conditions Indoor Air Temperature 20...

Page 16: ...ndoor Unit Complete Unit Fan Motor Fan Motor Compressor performance at Rating conditions Running Amps A 0 13 4 0 Power input Kw 0 031 0 890 Rating Conditions Indoor Air Temperature 20 C D B Outdoor Ai...

Page 17: ...6 2 Electric Wiring Diagram 6 3 System Wiring Diagram 17...

Page 18: ...0 8180 580 00 05 2009 R D 28 Reyrieux BP 131 01601 Tr voux CEDEX France T l 04 74 00 92 92 Fax 04 74 00 42 00 R C S Bourg en Bresse B 759 200 728...

Reviews: